Techniques of Frameless Robot-Assisted Deep Brain Stimulation and Accuracy Compared with the Frame-Based Technique

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Department of Neurology, Xuanwu Hospital of Capital Medical University, Beijing 100053, China. [2]Beijing Institute of Functional Neurosurgery, Xuanwu Hospital of Capital Medical University, Beijing 100053, China. [3]Department of Neurosurgery, Affiliated Hospital of Nantong University, Nantong University, Nantong 226001, China.
出处:
ISSN:

摘要:
Frameless robot-assisted deep brain stimulation (DBS) is an innovative technique for leads implantation. This study aimed to evaluate the accuracy and precision of this technique using the Sinovation SR1 robot.35 patients with Parkinson's disease who accepted conventional frame-based DBS surgery (n = 18) and frameless robot-assisted DBS surgery (n = 17) by the same group of neurosurgeons were analyzed. The coordinate of the tip of the intended trajectory was recorded as xi, yi, and zi. The actual position of lead implantation was recorded as xa, ya, and za. The vector error was calculated by the formula of √(xi - xa)2 + (yi - ya)2 + (zi - za)2 to evaluate the accuracy.The vector error was 1.52 ± 0.53 mm (range: 0.20-2.39 mm) in the robot-assisted group and was 1.77 ± 0.67 mm (0.59-2.98 mm) in the frame-based group with no significant difference between two groups (p = 0.1301). In 10.7% (n = 3) frameless robot-assisted implanted leads, the vector error was greater than 2.00 mm with a maximum offset of 2.39 mm, and in 35.5% (n = 11) frame-based implanted leads, the vector error was larger than 2.00 mm with a maximum offset of 2.98 mm. Leads were more posterior than planned trajectories in the robot-assisted group and more medial and posterior in the conventional frame-based group.Awake frameless robot-assisted DBS surgery was comparable to the conventional frame-based technique in the accuracy and precision for leads implantation.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2021]版:
大类 | 4 区 医学
小类 | 4 区 神经科学
最新[2023]版:
大类 | 3 区 医学
小类 | 3 区 神经科学
JCR分区:
出版当年[2020]版:
Q3 NEUROSCIENCES
最新[2023]版:
Q3 NEUROSCIENCES

影响因子: 最新[2023版] 最新五年平均 出版当年[2020版] 出版当年五年平均 出版前一年[2019版] 出版后一年[2021版]

第一作者:
第一作者机构: [1]Department of Neurology, Xuanwu Hospital of Capital Medical University, Beijing 100053, China.
共同第一作者:
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA: