Non-invasive intracranial pressure estimation using ultrasonographic measurement of area of optic nerve subarachnoid space

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing, China. [2]Beijing Institute of Ophthalmology, Beijing, China. [3]Department of Neurosurgery, Xuanwu Hospital Capital Medical University, Beijing, China. [4]Department of Neurosurgery, Beijing Tongren Hospital, Beijing, China. [5]School of Information and Electronics, Beijing Institute of Technology, Beijing, China. [6]Beijing Institute of Ophthalmology, Beijing, China hanruo.liu@hotmail.co.uk.
出处:
ISSN:

摘要:
To verify whether the area of the ONSAS (ONSASA) obtained by transorbital ultrasonography can be used to accurately evaluate the intracranial pressure (ICP).The recorded indexes included the optic nerve diameter, the optic nerve sheath diameter (ONSD), the width of both sides of the ONSAS (ONSASW) at 3 mm from the optic nerve head and the entire ONSASA outlined between 3 and 7 mm. After exploring and comparing five models to describe the relationship between body mass index (BMI), mean arterial blood pressure (MABP), ONSASA and ICP, the best model was determined.In all, 90 patients with neurological diseases undergoing continuous invasive ICP monitoring were included in the study. In the training group, the correlation coefficient for the association between the ICP and ONSASA (Pearson's correlation r=0.953) was higher than that for the association of the ICP with the ONSD (r=0.672; p<0.0001) and ONSASW at 3 mm behind the globe (r=0.691; p<0.0001). In the training group, the weighting function for prediction of the ICP was as follows: non-invasive ICP=2.050×ONSASA-0.051×BMI +0.036*MABP-5.837. With 20 mm Hg as the cut-off point for a high or low ICP, the sensitivity and specificity of ONSASA predicting ICP was 1.00 and 0.92. Receiver operator curve analysis revealed that the calculated cut-off value for predicting elevated ICP was 19.96 (area under curve= 0.960, 95% CI 0.865 to 1.00).Measurement of the ONSASA using ultrasonography can serve as a practical method for rapid and non-invasive quantification for evaluating ICP through an accurate mathematical formula with the BMI and MABP considered as contributing parameters.The study was registered in the Chinese Clinical Trial Registry (Study no ChiCTR2100045274).© Author(s) (or their employer(s)) 2022. No commercial re-use. See rights and permissions. Published by BMJ.

基金编号: Z191100001119072 82171051

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2022]版:
大类 | 2 区 医学
小类 | 1 区 眼科学
最新[2023]版:
大类 | 2 区 医学
小类 | 2 区 眼科学
JCR分区:
出版当年[2021]版:
Q1 OPHTHALMOLOGY
最新[2023]版:
Q1 OPHTHALMOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2021版] 出版当年五年平均 出版前一年[2020版] 出版后一年[2022版]

第一作者:
第一作者机构: [1]Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing, China.
共同第一作者:
通讯作者:
通讯机构: [5]School of Information and Electronics, Beijing Institute of Technology, Beijing, China. [6]Beijing Institute of Ophthalmology, Beijing, China hanruo.liu@hotmail.co.uk. [*1]Beijing Institute of Ophthalmology, Beijing, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院