当前位置: 首页 > 详情页

Cerebral tissue oximeter suitable for real-time regional oxygen saturation monitoring in multiple clinical settings

| 导出 | |

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Beijing Informat Sci & Technol Univ, Sch Instrumentat Sci & Optoelect Engn, Beijing 100192, Peoples R China [2]Capital Med Univ, Xuanwu Hosp, Beijing Inst Geriatr, Beijing 100053, Peoples R China [3]Chinese Acad Sci, Brainnetome Ctr, Inst Automat, Beijing 100190, Peoples R China [4]Chinese Acad Sci, Inst Automat, Natl Lab Pattern Recognit, Beijing 100190, Peoples R China [5]Capital Med Univ, Beijing Tiantan Hosp, Dept Anesthesiol, Beijing 100015, Peoples R China [6]Capital Med Univ, Xuanwu Hosp, Dept Neurosurg, Beijing 100053, Peoples R China [7]BUAA CCMU Adv Innovat Ctr Big Data Based Precis M, Beijing 100191, Peoples R China [8]Casibrain Technol Ltd Co, Res & Dev Dept, Beijing 100190, Peoples R China [9]Univ Elect Sci & Technol China, Sch Life Sci & Technol, Key Lab NeuroInformat, Minist Educ, Chengdu 625014, Peoples R China [10]Chinese Acad Sci, Ctr Excellence Brain Sci, Inst Automat, Beijing 100190, Peoples R China [11]Univ Queensland, Queensland Brain Inst, St Lucia, Qld 4072, Australia
出处:
ISSN:

关键词: Cerebral oximeter Near-infrared spectroscopy Regional cerebral oxygen saturation

摘要:
Maintenance of adequate blood perfusion and oxygen delivery is essential for cerebral metabolism. Cerebral oximeters based on near-infrared spectroscopy (NIRS) have been used for noninvasive, continuous, real-time monitoring of cerebral oxygen saturation and management of cerebral oxygen adequacy perioperatively and intraoperatively in various clinical situations, such as cardiac surgery, anesthesia, and cerebral auto-regulation. In this study, a portable and modular cerebral tissue oximeter (BRS-1) was designed for real-time detection of regional oxygen saturation over the brain, finger, or other targeted body tissues, as well as for wireless cerebral oxygenation monitoring. The compact and lightweight design of the system makes it easy to use during ambulance transport, in an emergency cart, or in an intensive care unit. The system performance of the BRS-1 oximeter was evaluated and compared with two US FDA-cleared cerebral oximeters during a controlled hypoxia experiment. The results showed that the BRS-1 oximeter can be used for real-time detection of cerebral desaturation with an accuracy similar to the two commercial oximeters. More importantly, the BRS-1 oximeter is capable of capturing cerebral oxygen saturation wirelessly. The BRS-1 cerebral oximeter can provide valuable insights for clinicians for real-time monitoring of cerebral/tissue perfusion and management of patients in prehospital and perioperative periods.

基金:

基金编号: 4214080 31571003 U1636121 82027802 82102220 Z181100003818004 KM202011232008 1202080880 KM202010025023 61975017

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2022]版:
大类 | 2 区 工程技术
小类 | 3 区 神经科学
最新[2023]版:
大类 | 3 区 工程技术
小类 | 3 区 神经科学
JCR分区:
出版当年[2021]版:
Q3 NEUROSCIENCES
最新[2023]版:
Q2 NEUROSCIENCES

影响因子: 最新[2023版] 最新五年平均 出版当年[2021版] 出版当年五年平均 出版前一年[2020版] 出版后一年[2022版]

第一作者:
第一作者机构: [1]Beijing Informat Sci & Technol Univ, Sch Instrumentat Sci & Optoelect Engn, Beijing 100192, Peoples R China
共同第一作者:
通讯作者:
通讯机构: [2]Capital Med Univ, Xuanwu Hosp, Beijing Inst Geriatr, Beijing 100053, Peoples R China [3]Chinese Acad Sci, Brainnetome Ctr, Inst Automat, Beijing 100190, Peoples R China [4]Chinese Acad Sci, Inst Automat, Natl Lab Pattern Recognit, Beijing 100190, Peoples R China [6]Capital Med Univ, Xuanwu Hosp, Dept Neurosurg, Beijing 100053, Peoples R China [7]BUAA CCMU Adv Innovat Ctr Big Data Based Precis M, Beijing 100191, Peoples R China [8]Casibrain Technol Ltd Co, Res & Dev Dept, Beijing 100190, Peoples R China [9]Univ Elect Sci & Technol China, Sch Life Sci & Technol, Key Lab NeuroInformat, Minist Educ, Chengdu 625014, Peoples R China [10]Chinese Acad Sci, Ctr Excellence Brain Sci, Inst Automat, Beijing 100190, Peoples R China [11]Univ Queensland, Queensland Brain Inst, St Lucia, Qld 4072, Australia
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16461 今日访问量:0 总访问量:871 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院