The Interpretation of Mirror Pattern Bands During Oligoclonal Immunoglobulin Isoelectric Focusing Electrophoresis: A Retrospective Study

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Capital Med Univ, Xuanwu Hosp, Dept Clin Lab, Beijing, Peoples R China
出处:
ISSN:

关键词: oligoclonal bands mirror pattern bands isoelectric focusing electrophoresis immunofixation electrophoresis

摘要:
Objective Mirror patterns are incidental types that accompany the analysis of the oligoclonal band (OCB) in cerebrospinal fluid (CSF). However, their interpretation remains controversial. In this study, we analyzed all graphic results of mirror patterns from 86 patients to provide an optimal interpretation scheme for mirror patterns. Methods Matched CSF and serum specimens were obtained from patients with various neurological disorders that required OCB analysis. A total of 86 patients were screened and serum immunofixation electrophoresis (IFE) was performed in all 86. The interobserver agreement for interpreting mirror patterns by visual inspection was tested. The method agreement between the visual inspection and IFE was also evaluated. The CSF/serum albumin quotient (QALB) was calculated to determine the blood-brain barrier integrity of all patients. Results Of the 86 patients with mirror patterns, 19.8% (17/86) had typical mirror bands and most (80.2%) had atypical mirror bands. There was a good agreement between the 2 observers in interpreting typical mirror patterns. However, kappa statistics analysis showed poor agreement regarding the interpretation of atypical mirror bands by visual observation alone (kappa value, -0.026 to 0.314 between 2 observers). The disagreement was pronounced between the visual inspection and validation of IFE (kappa value, -0.0238 to 0.176 between the first observer and IFE; -0.322 to 0.118 between the second observer and IFE). The normal QALB rates in the type V groups were significantly higher than those in the type IV group and the positive QALB rates in the type IV were significantly higher than those in the type V. Conclusion Visual inspection to interpret mirror pattern bands is unreliable. Considering the completely different clinical significance between type IV and type V and high risk of potential misinterpretations, it is necessary to perform IFE on all the atypical mirror types to discriminate atypical type IV from atypical type V.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2022]版:
大类 | 4 区 医学
小类 | 4 区 医学实验技术
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 医学实验技术
JCR分区:
出版当年[2021]版:
Q4 MEDICAL LABORATORY TECHNOLOGY
最新[2023]版:
Q4 MEDICAL LABORATORY TECHNOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2021版] 出版当年五年平均 出版前一年[2020版] 出版后一年[2022版]

第一作者:
第一作者机构: [1]Capital Med Univ, Xuanwu Hosp, Dept Clin Lab, Beijing, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院