当前位置: 首页 > 详情页

A flexible omnidirectional rotating magnetic array for MRI-safe transdermal wireless energy harvesting through flexible electronics

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE ◇ 自然指数

机构: [1]Department of Biomedical Engineering, Tianjin University, 92 Weijin Road, Tianjin 300072, China. [2]Department of Radiology and Nuclear Medicine, Xuanwu Hospital, Capital Medical University, 45 Changchun Street, Beijing 100053, China. [3]Beijing Key Laboratory of MRI and Brain Informatics, Xuanwu Hospital, Capital Medical University, 45 Changchun Street, Beijing 100053, China. [4]Institute of Wearable Technology and Bioelectronics, Qiantang Science and Technology Innovation Center, 1002 23rd Street, Hangzhou 310018, China. [5]Flexible Wearable Technology Research Center, Institute of Flexible Electronics Technology of Tsinghua, 906 Yatai Road, Jiaxing 314033, China.
出处:
ISSN:

摘要:
Magnetic resonance imaging (MRI)-safe implantable wireless energy harvester offers substantial benefits to patients suffering from brain disorders, hearing impairment, and arrhythmias. However, rigid magnets in cutting-edge systems with limited numbers of rotation axis impose high risk of device dislodgement and magnet failure. Here, a flexible omnidirectional rotating magnetic array (FORMA) and a flexible MRI-safe implantable wireless energy-harvesting system have been developed. Miniaturized flexible magnetic balls 1 millimeter in diameter achieved by molding three-dimensional printed templates can rotate freely in elastomer cavities and supply a magnetic force of 2.14 Newtons at a distance of 1 millimeter between an implantable receiver and a wearable transceiver. The system can work stably under an acceleration of 9g and obtain a power output of 15.62 decibel milliwatts at a transmission frequency of 8 megahertz. The development of the FORMA may lead to life-long flexible and batteryless implantable systems and offers the potential to promote techniques for monitoring and treating acute and chronic diseases.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2022]版:
大类 | 1 区 综合性期刊
小类 | 1 区 综合性期刊
最新[2023]版:
大类 | 1 区 综合性期刊
小类 | 1 区 综合性期刊
JCR分区:
出版当年[2021]版:
Q1 MULTIDISCIPLINARY SCIENCES
最新[2023]版:
Q1 MULTIDISCIPLINARY SCIENCES

影响因子: 最新[2023版] 最新五年平均 出版当年[2021版] 出版当年五年平均 出版前一年[2020版] 出版后一年[2022版]

第一作者:
第一作者机构: [1]Department of Biomedical Engineering, Tianjin University, 92 Weijin Road, Tianjin 300072, China.
共同第一作者:
通讯作者:
通讯机构: [1]Department of Biomedical Engineering, Tianjin University, 92 Weijin Road, Tianjin 300072, China. [4]Institute of Wearable Technology and Bioelectronics, Qiantang Science and Technology Innovation Center, 1002 23rd Street, Hangzhou 310018, China. [5]Flexible Wearable Technology Research Center, Institute of Flexible Electronics Technology of Tsinghua, 906 Yatai Road, Jiaxing 314033, China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题