Performance evaluation of an AI-based preoperative planning software application for automatic selection of pedicle screws based on computed tomography images
机构:[1]Capital Med Univ, Xuanwu Hosp, Dept Neurosurg, Beijing, Peoples R China首都医科大学宣武医院[2]China Int Neurosci Inst CHINA INI, Spine Ctr, Beijing, Peoples R China[3]Univ Hong Kong, Li Ka Shing Fac Med, Dept Orthopaed & Traumatol, Hong Kong, Peoples R China[4]Univ Hong Kong, Shenzhen Hosp, Dept Orthopaed & Traumatol, Shenzhen, Peoples R China[5]Chinese Acad Sci, Shenzhen Inst Adv Technol, Dept Pharmaceut Mat Sci & Translat Med, Shenzhen, Peoples R China
IntroductionRecent neurosurgical applications based on artificial intelligence (AI) have demonstrated its potential in surgical planning and anatomical measurement. We aimed to evaluate the performance of an AI planning software application on screw length/diameter selection and insertion accuracy in comparison with freehand surgery.MethodsA total of 45 patients with 208 pedicle screw placements on thoracolumbar segments were included in this analysis. The novel AI planning software was developed based on a deep learning model. AI-based pedicle screw placements were selected on the basis of preoperative computed tomography (CT) data, and freehand surgery screw placements were observed based on postoperative CT data. The performance of AI pedicle screw placements was evaluated on the components of screw length, diameter, and Gertzbein grade in comparison with the results achieved by freehand surgery.ResultsAmong 208 pedicle screw placements, the average screw length/diameters selected by the AI model and used in freehand surgery were 48.65 & PLUSMN; 5.99 mm/7.39 & PLUSMN; 0.42 mm and 44.78 & PLUSMN; 2.99 mm/6.1 & PLUSMN; 0.27 mm, respectively. Among AI screw placements, 85.1% were classified as Gertzbein Grade A (no cortical pedicle breach); among free-hand surgery placements, 64.9% were classified as Gertzbein Grade A.ConclusionThe novel AI planning software application could provide an accessible and safe pedicle screw placement strategy in comparison with traditional freehand pedicle screw placement strategies. The choices of pedicle screw dimensional parameters made by the model, including length and diameter, may provide potential inspiration for real clinical discretion.
第一作者机构:[1]Capital Med Univ, Xuanwu Hosp, Dept Neurosurg, Beijing, Peoples R China[2]China Int Neurosci Inst CHINA INI, Spine Ctr, Beijing, Peoples R China
共同第一作者:
通讯作者:
通讯机构:[1]Capital Med Univ, Xuanwu Hosp, Dept Neurosurg, Beijing, Peoples R China[2]China Int Neurosci Inst CHINA INI, Spine Ctr, Beijing, Peoples R China[3]Univ Hong Kong, Li Ka Shing Fac Med, Dept Orthopaed & Traumatol, Hong Kong, Peoples R China[4]Univ Hong Kong, Shenzhen Hosp, Dept Orthopaed & Traumatol, Shenzhen, Peoples R China[5]Chinese Acad Sci, Shenzhen Inst Adv Technol, Dept Pharmaceut Mat Sci & Translat Med, Shenzhen, Peoples R China
推荐引用方式(GB/T 7714):
Jia Shanhang,Weng Yuanzhi,Wang Kai,et al.Performance evaluation of an AI-based preoperative planning software application for automatic selection of pedicle screws based on computed tomography images[J].FRONTIERS IN SURGERY.2023,10:doi:10.3389/fsurg.2023.1247527.
APA:
Jia, Shanhang,Weng, Yuanzhi,Wang, Kai,Qi, Huan,Yang, Yuhua...&Wu, Hao.(2023).Performance evaluation of an AI-based preoperative planning software application for automatic selection of pedicle screws based on computed tomography images.FRONTIERS IN SURGERY,10,
MLA:
Jia, Shanhang,et al."Performance evaluation of an AI-based preoperative planning software application for automatic selection of pedicle screws based on computed tomography images".FRONTIERS IN SURGERY 10.(2023)