当前位置: 首页 > 详情页

Relation of lumbar intervertebral disc height and severity of disc degeneration based on Pfirrmann scores

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Department of Orthopaedics, Xuanwu Hospital Capital Medical University, Xicheng District, Beijing, China.
出处:

关键词: Lumbar spine Intervertebral disc degeneration Disc height Magnetic resonance image Agreement Reliability

摘要:
Disc height (DH) change is considered one of the most critical factors in assessing intervertebral disc degeneration (IVD). Pfirrmann et al. developed a scoring system for disc degeneration evaluation based on changes in DH in magnetic resonance imaging (MRI). While the relationship between DH measurements and Pfirrmann scores for disc degeneration has been explored, the validity of different DH measuring techniques or their connection with disc degeneration is yet uncertain. The present study investigates intra-rater and inter-rater agreement and reliability of different DH measurement methods on MRI and evaluates the relationship between different DH measurement methods and Pfirrmann scores of IVD degeneration, as well as between different Pfirrmann scores and clinical outcomes.Adult patients with MRI scans of the lumbar spine were recruited. Eight DH measuring techniques were tested for intra-rater and inter-rater agreement and reliability. Bland and Altman's Limits of Agreement (LOA) was used to evaluate intra-rater and inter-rater agreements. Intra-rater and inter-rater reliability were evaluated using intra-class correlations (ICC) with 95 % confidence intervals (95 % CI). The association between DH and Pfirrmann scores was examined using one-way ANOVA.Excellent intra-rater reliability was reported for 332 participants on DH (ranging from 0.912 (0.901, 0.923) to 0.973 (0.964, 0.981) and from 0.902 (0.892, 0.915) to 0.975 (0.962, 0.985) by two independent raters). All measuring methods had high intra-rater agreement, except for methods 4 and 5. All methods had good-to-excellent of inter-rater reliability on DH (ICCs ranging from 0.812 (0.795, 0.828) to 0.995 (0.994, 0.995)) except for the posterior disc material length of method 5 (ICC 0.740 (0.718, 0.761)). Methods 1 to 6 for evaluating DH in patients with spondylolisthesis had poor inter-rater reliability. The IVD levels with grades IV and V in Pfirrmann scores had significantly lower DH than the IVD levels with grades I to III in Pfirrmann scores. IVD levels with grades IV and V in Pfirrmann scores had significantly higher VAS and ODI than IVD levels with grades I in Pfirrmann scores.A good-to-excellent intra-rater and inter-rater reliability was achieved on most DH measuring methods on MRI following a standardized and structured protocol. However, small anatomical structures and different tissue borders could influence measurements. Additionally, DH can differentiate between grade IV and V Pfirrmann scores, and severe IVD degeneration (IV and V Pfirrmann) is linked to clinical outcomes.© 2023 The Authors.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2022]版:
大类 | 4 区 综合性期刊
小类 | 4 区 综合性期刊
最新[2025]版:
大类 | 4 区 综合性期刊
小类 | 4 区 综合性期刊
JCR分区:
出版当年[2021]版:
Q2 MULTIDISCIPLINARY SCIENCES
最新[2023]版:
Q1 MULTIDISCIPLINARY SCIENCES

影响因子: 最新[2023版] 最新五年平均 出版当年[2021版] 出版当年五年平均 出版前一年[2020版] 出版后一年[2022版]

第一作者:
第一作者机构: [1]Department of Orthopaedics, Xuanwu Hospital Capital Medical University, Xicheng District, Beijing, China.
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16991 今日访问量:1 总访问量:905 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院