Subpixel motion artifacts correction and motion estimation for 3D-OCT

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]School of Medical Technology, Beijing Institute of Technology, Beijing, China [2]Department of Anesthesiology, Beijing Chaoyang Hospital, Capital Medical University, Beijing, China [3]State Key Laboratory of Low-dimensional Quantum Physics and Center for Atomic and Molecular Nanoscience, Department of Physics, Tsinghua University and Collaborative Innovation Center of Quantum Matter, Beijing, China [4]China-America Institute of Neuroscience and Beijing Institute of Geriatrics, Xuanwu Hospital, Capital Medical University, Beijing, China [5]Beijing Institute for Brain Disorders, Capital Medical University, Beijing, China
出处:
ISSN:

关键词: anterior segment motion artifacts correction motion estimation optical coherence tomography

摘要:
A number of hardware-based and software-based strategies have been suggested to eliminate motion artifacts for improvement of 3D-optical coherence tomography (OCT) image quality. However, the hardware-based strategies have to employ additional hardware to record motion compensation information. Many software-based strategies have to need additional scanning for motion correction at the expense of longer acquisition time. To address this issue, we propose a motion artifacts correction and motion estimation method for OCT volumetric imaging of anterior segment, without requirements of additional hardware and redundant scanning. The motion correction effect with subpixel accuracy for in vivo 3D-OCT has been demonstrated in experiments. Moreover, the physiological information of imaging object, including respiratory curve and respiratory rate, has been experimentally extracted using the proposed method. The proposed method offers a powerful tool for scientific research and clinical diagnosis in ophthalmology and may be further extended for other biomedical volumetric imaging applications.

基金:
语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2023]版:
大类 | 3 区 物理与天体物理
小类 | 2 区 生物物理 3 区 生化研究方法 3 区 光学
最新[2023]版:
大类 | 3 区 物理与天体物理
小类 | 2 区 生物物理 3 区 生化研究方法 3 区 光学
JCR分区:
出版当年[2022]版:
Q2 OPTICS Q3 BIOCHEMICAL RESEARCH METHODS Q3 BIOPHYSICS
最新[2023]版:
Q3 BIOCHEMICAL RESEARCH METHODS Q3 BIOPHYSICS Q3 OPTICS

影响因子: 最新[2023版] 最新五年平均 出版当年[2022版] 出版当年五年平均 出版前一年[2021版] 出版后一年[2023版]

第一作者:
第一作者机构: [1]School of Medical Technology, Beijing Institute of Technology, Beijing, China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16461 今日访问量:0 总访问量:871 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院