Comparison of robot versus fluoroscopy-assisted pedicle screw instrumentation in adolescent idiopathic scoliosis surgery: a Meta-analysis

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Shanxi Med Univ, Shanxi Prov Peoples Hosp, Clin Med Coll 5, Taiyuan 030001, Peoples R China [2]Xiongan Xuanwu Hosp, Xiongan New Area, Hangzhou, Zhejiang, Peoples R China [3]Shanxi Prov Peoples Hosp, Taiyuan 030001, Peoples R China
出处:
ISSN:

关键词: Adolescent idiopathic scoliosis Robot Pedicle screw Meta-analysis

摘要:
AimTo investigate the safety and accuracy of robot-assisted pedicle screw placement in adolescent idiopathic scoliosis (AIS) surgery.MethodsPubMed, Medline, Embase, Cochrane Library, Web of Science, CNKI, and EMCC databases were searched for studies utilizing the clinical data of adolescent idiopathic scoliosis patients (robot-assisted and fluoroscopy-assisted group) who underwent posterior pedicle screw fixation to collect preoperative, postoperative and follow-up indexes and imaging parameters, including screw implantation accuracy, the number of intraoperative fluoroscopy times, amount of bleeding, operation time, postoperative VAS score and postoperative Cobb angle.ResultsSix studies were included in this meta-analysis, including 154 patients in the intervention group and 171 patients in the control group. Our results showed that screw implantation accuracy (WMD 1.07, 95% CI (1.01,1.14), P = 0.03) was higher than that in the control group. The number of intraoperative fluoroscopy times (WMD -6.11, 95% CI (-9.60, -2.62), P = 0.0006) and operation time (WMD 31.52, 95% CI (5.70,57.35), P = 0.02) in the robot group were less, and the differences were statistically significant. Intraoperative blood (WMD -59.05, 95% CI (-212.81,94.70), P = 0.45), postoperative VAS score (WMD -0.07, 95% CI (-0.24,0.11), P = 0.46), preoperative Cobb angle (WMD 0.79, 95% CI (-1.12,2.69), P = 0.42) (Fig. 7), postoperative Cobb angle (WMD -0.25, 95% CI (-1.12,0.62), P = 0.57) (Fig. 8) had no statistical significance in the robot group compared with control group.ConclusionThe robot navigation system can improve screw implantation accuracy and reduce the operation time and radiation exposure during the operation.

基金:
语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2023]版:
大类 | 3 区 医学
小类 | 3 区 骨科 3 区 风湿病学
最新[2023]版:
大类 | 3 区 医学
小类 | 3 区 骨科 3 区 风湿病学
JCR分区:
出版当年[2022]版:
Q2 ORTHOPEDICS Q4 RHEUMATOLOGY
最新[2023]版:
Q2 ORTHOPEDICS Q3 RHEUMATOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2022版] 出版当年五年平均 出版前一年[2021版] 出版后一年[2023版]

第一作者:
第一作者机构: [1]Shanxi Med Univ, Shanxi Prov Peoples Hosp, Clin Med Coll 5, Taiyuan 030001, Peoples R China
共同第一作者:
通讯作者:
通讯机构: [1]Shanxi Med Univ, Shanxi Prov Peoples Hosp, Clin Med Coll 5, Taiyuan 030001, Peoples R China [3]Shanxi Prov Peoples Hosp, Taiyuan 030001, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院