Development of a clinical and ultrasonic parameter-based nomogram model to predict restenosis after superficial femoral artery stenting

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Department of Ultrasound in Medicine, Beijing Luhe Hospital, Capital Medical University, Beijing, China [2]Vascular Ultrasound Department, Xuanwu Hospital Capital Medical University, Beijing, China [3]Department of Ultrasound in Medicine, East Hospital Affiliated to Tongji University, Shanghai, China [4]Division of Vascular Surgery and Endovascular Therapy, Department of Surgery, Yale School of Medicine, New Haven, CT.
出处:
ISSN:

摘要:
Prediction of in-stent restenosis (ISR) is clinically important for patients with peripheral artery disease in their superficial femoral arteries (SFA) who have been treated with stenting. The aim of this study was to construct and validate a predictive model for ISR after SFA stenting based on a series of clinical and ultrasonic parameters.This retrospective study included 381 patients who were treated with self-expanding bare nitinol stents in their SFA at our hospital between January 1, 2018, and January 1, 2022. These patients were randomly allocated to a training cohort (266 patients) or a validation cohort (115). Clinical and ultrasonic parameters related to ISR (>50%) in the SFA at 12 months were derived by univariable and multivariable logistic regression analyses to create a nomogram model predictive of risk of ISR. Receiver operating characteristic (ROC) curve analyses were used to assess the recognition ability of the model. A calibration curve was used to evaluate the model's calibration ability, and decision curve analysis was used to validate the nomogram's clinical utility.Logistic regression analyses showed that sex, echogenicity of the target plaque, preoperative arterial runoff score, preoperative popliteal artery flow rate, lesion length, and residual diameter were risk factors for ISR; these parameters were used to construct the nomogram model. Internal and external validation showed that the areas under the ROC curves were 0.82 (95%CI: 0.77-0.87) and 0.70 (95%CI: 0.60-0.79), respectively, suggesting good recognition ability of the model. Additionally, calibration curves for the predictive model indicated good calibration, and decision curve analysis demonstrated clinical utility of the model.This novel nomogram that predicts ISR after SFA stenting demonstrated excellent discriminatory power, calibration capacity, and clinical usefulness.Copyright © 2025. Published by Elsevier Inc.

基金:
语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2025]版:
大类 | 4 区 医学
小类 | 4 区 外周血管病 4 区 外科
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 外周血管病 4 区 外科
JCR分区:
出版当年[2023]版:
Q3 PERIPHERAL VASCULAR DISEASE Q3 SURGERY
最新[2023]版:
Q3 PERIPHERAL VASCULAR DISEASE Q3 SURGERY

影响因子: 最新[2023版] 最新五年平均 出版当年[2023版] 出版当年五年平均 出版前一年[2022版]

第一作者:
第一作者机构: [1]Department of Ultrasound in Medicine, Beijing Luhe Hospital, Capital Medical University, Beijing, China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:17069 今日访问量:2 总访问量:918 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院