当前位置: 首页 > 详情页

Relationship between soluble Semaphorin4D and cognitive impairment in patients with obstructive sleep apnea-hypopnea syndrome

文献详情

资源类型:

收录情况: ◇ SCIE

机构: [1]Department of Respiratory Medicine, Sleeping Center, The Second Affiliated Hospital of Soochow University, No 1055, Sanxiang Road, Suzhou City 215004, China [2]Department of Cardiology, The Second Affiliated Hospital of Soochow University, No 1055, Sanxiang Road, Suzhou City, China [3]Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore [4]Cardiovascular Research Institute, National University Heart Centre Singapore, Singapore, Singapore [5]Department of Mathematics and Statistics, La Trobe University, Melbourne, Australia
出处:
ISSN:

关键词: Obstructive sleep apnea-hypopnea syndrome Cognition impairment Semaphorin4D Predictor

摘要:
To investigate the relationship between plasma soluble semaphorin4D (sSema4D) and obstructive sleep apnea-hypopnea syndrome (OSAHS), and to ascertain the effect of sSema4D on cognitive dysfunction in patients with OSAHS. We prospectively recruited 30 men with moderate-severe OSAHS diagnosed by polysomnography, and 30 healthy controls with matched gender, age and education level. Montreal Cognitive Assessment (MoCA) was administered to determine cognitive impairment. Plasma sSema4D levels were measured. Among the total of 60 study patients, the overall plasma sSema4D level was 7.81 +/- 1.91 ng/ml. Plasma sSema4D level in OSAHS group was significantly higher than that in controls (8.92 +/- 1.79 vs 6.70 +/- 1.28 ng/ml, p < 0.001). In OSAHS subgroup, patients with cognition impairment (CI) had higher plasma sSema4D level (10.50 +/- 1.16 vs 8.00 +/- 1.41 ng/ml, p < 0.001) and apnea-hypopnea index (AHI) (48.1 +/- 14.0 vs 30.3 +/- 9.2, p < 0.001) than those in non-CI group. Multiple logistic regression revealed that plasma sSema4D level (AOR 2.824, 95 % CI 1.562-5.103; p = 0.001) and BMI (AOR 2.237, 95 % CI 1.345-3.722; p = 0.002) were significantly associated with OSAHS, and plasma sSema4D was a significant predictor of CI after adjustment for other confounders (AOR 4.956, 95 % CI 1.581-15.538; p = 0.006). OSAHS patients, especially those with cognition impairment, are featured by elevated plasma sSema4D level, and sSema4D is significantly associated with cognition impairment induced by OSAHS.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2016]版:
大类 | 4 区 医学
小类 | 3 区 耳鼻喉科学
最新[2023]版:
大类 | 3 区 医学
小类 | 3 区 耳鼻喉科学
JCR分区:
出版当年[2015]版:
Q2 OTORHINOLARYNGOLOGY
最新[2023]版:
Q2 OTORHINOLARYNGOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2015版] 出版当年五年平均 出版前一年[2014版] 出版后一年[2016版]

第一作者:
第一作者机构: [1]Department of Respiratory Medicine, Sleeping Center, The Second Affiliated Hospital of Soochow University, No 1055, Sanxiang Road, Suzhou City 215004, China
共同第一作者:
通讯作者:
通讯机构: [1]Department of Respiratory Medicine, Sleeping Center, The Second Affiliated Hospital of Soochow University, No 1055, Sanxiang Road, Suzhou City 215004, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院