Comparison of Diagnostic Performance of Three-Dimensional Positron Emission Mammography versus Whole Body Positron Emission Tomography in Breast Cancer
机构:[1]Department of Molecular Imaging and Nuclear Medicine and Key Laboratory of Cancer Prevention and Therapy and Key Laboratory of Breast Cancer Prevention and Therapy, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center for Cancer, Tianjin 300060, China[2]PET Center of XuanWu Hospital, Capital Medical University, Beijing, China首都医科大学宣武医院[3]Division of Nuclear Technology and Applications, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China[4]Beijing Engineering Research Center of Radiographic Techniques and Equipment, Beijing 100049, China
Objective. To compare the diagnostic performance of three-dimensional (3D) positron emission mammography (PEM) versus whole body positron emission tomography (WBPET) for breast cancer. Methods. A total of 410 women with normal breast or benign or highly suspicious malignant tumors were randomized at 1 : 1 ratio to undergo 3D-PEM followed by WBPET or WBPET followed by 3D-PEM. Lumpectomy or mastectomy was performed on eligible participants after the scanning. Results. The sensitivity and specificity of 3D-PEM were 92.8% and 54.5%, respectively. WBPET showed a sensitivity of 95.7% and specificity of 56.8%. After exclusion of the patients with lesions beyond the detecting range of the 3D-PEM instrument, 3D-PEM showed higher sensitivity thanWBPET(97.0% versus 95.5%, P = 0.913), particularly for small lesions (< 1 cm) (72.0% versus 60.0%, P = 0.685). Conclusions. The 3D-PEM appears more sensitive to small lesions thanWBPET but may fail to detect lesions that are beyond the detecting range. This study was approved by the Ethics Committee (E2012052) at the Tianjin Medical University Cancer Institute and Hospital (Tianjin, China). The instrument positron emission mammography (PEMi) was approved by China State Food and Drug Administration under the registration number 20153331166.
基金:
the National Natural Science Foundation of China (Grants nos. 81302003, 81501984, and 81601377),
the National Science and Technology Major Project (Grant no. 2013ZX09303001),
Tianjin Natural Science Fund (16JCZDJC35200, 17JCYBJC25100),
Incubation Project of National Clinical Research Center for Cancer (N14B09),
Tianjin Medical University Cancer Institute and Hospital Fund (Y1601),
the Science & TechnologyDevelopment Fund of Tianjin EducationCommission for Higher Education (no. 20120109).
第一作者机构:[1]Department of Molecular Imaging and Nuclear Medicine and Key Laboratory of Cancer Prevention and Therapy and Key Laboratory of Breast Cancer Prevention and Therapy, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center for Cancer, Tianjin 300060, China
通讯作者:
通讯机构:[1]Department of Molecular Imaging and Nuclear Medicine and Key Laboratory of Cancer Prevention and Therapy and Key Laboratory of Breast Cancer Prevention and Therapy, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center for Cancer, Tianjin 300060, China
推荐引用方式(GB/T 7714):
Dong Dai ,Xiuyu Song ,Man Wang ,et al.Comparison of Diagnostic Performance of Three-Dimensional Positron Emission Mammography versus Whole Body Positron Emission Tomography in Breast Cancer[J].CONTRAST MEDIA & MOLECULAR IMAGING.2017,2017:doi:10.1155/2017/5438395.
APA:
Dong Dai,,Xiuyu Song,,Man Wang,,Lin Li,,Wenchao Ma,...&Yusheng Su.(2017).Comparison of Diagnostic Performance of Three-Dimensional Positron Emission Mammography versus Whole Body Positron Emission Tomography in Breast Cancer.CONTRAST MEDIA & MOLECULAR IMAGING,2017,
MLA:
Dong Dai,,et al."Comparison of Diagnostic Performance of Three-Dimensional Positron Emission Mammography versus Whole Body Positron Emission Tomography in Breast Cancer".CONTRAST MEDIA & MOLECULAR IMAGING 2017.(2017)