当前位置: 首页 > 详情页

Early Detection and Quantification of Cerebral Venous Thrombosis by Magnetic Resonance Black-Blood Thrombus Imaging

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

机构: [1]Departments of Radiology,Xuanwu Hospital, Capital Medical University,Beijing, China [2]Departments of Emergency,Xuanwu Hospital, Capital Medical University,Beijing, China [3]Departments of Neurosurgery,Xuanwu Hospital, Capital Medical University,Beijing, China [4]Biomedical Imaging Research Institute, Cedars Sinai Medical Center, Los Angeles, CA [5]MR Research and Development, Siemens Healthcare, Los Angeles, CA
出处:
ISSN:

关键词: magnetic resonance imaging sinus thrombosis intracranial venous thrombosis

摘要:
Background and Purpose-Early diagnosis of cerebral venous thrombosis (CVT) is currently a major clinical challenge. We proposed a novel magnetic resonance black-blood thrombus imaging technique (MRBTI) for detection and quantification of CVT. Methods-MRBTI was performed on 23 patients with proven CVT and 24 patients with negative CVT confirmed by conventional imaging techniques. Patients were divided into 2 groups based on the duration of clinical onset: <= 7 days (group 1) and between 7 and 30 days (group 2). Signal/noise ratio was calculated for the detected thrombus, and contrast/noise ratio was measured between thrombus and lumen and also between thrombus and brain tissue. The feasibility of using MRBTI for thrombus volume measurement was explored, and total thrombus volume was calculated for each patient. Results-In 23 patients with proven CVT, MRBTI correctly identified 113 of 116 segments with a sensitivity of 97.4%. Thrombus signal/noise ratio was 153 +/- 57 and 261 +/- 95 for group 1 (n=10) and group 2 (n=13), respectively (P<0.01). Thrombus to lumen contrast/noise ratio was 149 +/- 57 and 256 +/- 94 for group 1 and group 2, respectively. Thrombus to brain tissue contrast/noise ratio was 41 +/- 36 and 120 +/- 63 (P<0.01), respectively. Quantification of thrombus volume was successfully conducted in all patients with CVT, and mean volume of thrombus was 10.5 +/- 6.9 mL. Conclusions-The current findings support that with effectively suppressed blood signal, MRBTI allows selective visualization of thrombus as opposed to indirect detection of venous flow perturbation and can be used as a promising first-line diagnostic imaging tool.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2015]版:
大类 | 2 区 医学
小类 | 2 区 临床神经病学 2 区 外周血管病
最新[2025]版:
大类 | 1 区 医学
小类 | 1 区 临床神经病学 1 区 外周血管病
JCR分区:
出版当年[2014]版:
Q1 CLINICAL NEUROLOGY Q1 PERIPHERAL VASCULAR DISEASE
最新[2023]版:
Q1 CLINICAL NEUROLOGY Q1 PERIPHERAL VASCULAR DISEASE

影响因子: 最新[2023版] 最新五年平均 出版当年[2014版] 出版当年五年平均 出版前一年[2013版] 出版后一年[2015版]

第一作者:
第一作者机构: [1]Departments of Radiology,Xuanwu Hospital, Capital Medical University,Beijing, China [4]Biomedical Imaging Research Institute, Cedars Sinai Medical Center, Los Angeles, CA
共同第一作者:
通讯作者:
通讯机构: [*1]No. 45 Changchun St, Xuanwu District, Beijing 100053, China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16996 今日访问量:0 总访问量:905 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院