Effect of a novel motion correction algorithm (SSF) on the image quality of coronary CTA with intermediate heart rates: Segment-based and vessel-based analyses
Purpose: To evaluate the effect of SnapShot Freeze (SSF) reconstruction at an intermediate heart-rate (HR) range (65-75 bpm) and compare this method with single-sector reconstruction and bi-sector reconstruction on segmental and vessel bases in retrospective coronary computed tomography angiography (CCTA). Materials and methods: Retrospective electrocardiogram-gated CCTA was performed on 37 consecutive patients with HR between 65 and 75 bpm using a 64-row CT scanner. Retrospective single-sector reconstruction, bi-sector reconstruction, and SSF were performed for each patient. Multi-phase single-sector reconstruction was performed to select the optimal phase. SSF and bi-sector images were also reconstructed at the optimal phase. The images were interpreted in an intent-to-diagnose fashion by two experienced readers using a 5-point scale, with 3 points as diagnostically acceptable. Image quality among the three reconstruction groups were compared on per-patient, per-vessel, and per-segment bases. Results: The average HR of the enrolled patients was 69.4 +/- 2.7 bpm. A total of 111 vessels and 481 coronary segments were assessed. SSF provided significantly higher interpretability of the coronary segments than bi-sector reconstructions. The qualified and excellent rates of SSF (97.9% and 82.3%) were significantly higher than those of single-sector (92.9% and 66.3%) and bi-sector (90.9% and 64.7%) reconstructions. The image quality score (IQS) using SSF was also significantly higher than those of single-sector and bi-sector reconstructions both on per-patient and per-vessel bases. On per-segment analysis, IQS was improved in most segments (9114). Conclusion: The SSF algorithm can provide acceptable diagnostic image quality in coronary CTA for patients with intermediate HR. (C) 2014 Elsevier Ireland Ltd. All rights reserved.
基金:
the National Natural Science Foun-dation of China (30970821)
Xinjiang Corps Medical ScienceProject (2012AB015) of China.
第一作者机构:[1]Department of Radiology, Xuanwu Hospital, Capital Medical University, 45 Changchun Street, Xicheng District, Beijing 100053, China
通讯作者:
通讯机构:[1]Department of Radiology, Xuanwu Hospital, Capital Medical University, 45 Changchun Street, Xicheng District, Beijing 100053, China
推荐引用方式(GB/T 7714):
Qianwen Li ,Pengyu Li ,Zhuangzhi Su ,et al.Effect of a novel motion correction algorithm (SSF) on the image quality of coronary CTA with intermediate heart rates: Segment-based and vessel-based analyses[J].EUROPEAN JOURNAL OF RADIOLOGY.2014,83(11):2024-2432.doi:10.1016/j.ejrad.2014.08.002.
APA:
Qianwen Li,,Pengyu Li,,Zhuangzhi Su,,Xinyu Yao,,Yan Wang,...&Kuncheng Li.(2014).Effect of a novel motion correction algorithm (SSF) on the image quality of coronary CTA with intermediate heart rates: Segment-based and vessel-based analyses.EUROPEAN JOURNAL OF RADIOLOGY,83,(11)
MLA:
Qianwen Li,,et al."Effect of a novel motion correction algorithm (SSF) on the image quality of coronary CTA with intermediate heart rates: Segment-based and vessel-based analyses".EUROPEAN JOURNAL OF RADIOLOGY 83..11(2014):2024-2432