Purpose: To assess and compare the radiation dose of DynaCT in phantoms to that of MSCT. Methods and materials: A male Anderson Radiation Therapy 200 phantom with embedded thermoluminescence dosimeters (TLDs) was scanned with DynaCT (Axiom Artis dTA, Siemens Healthcare, Forchheim, Germany) and MSCTs (MSCT1: Lightspeed VCT, GE, Milwaukee, USA; MSCT2: Sensation Cardiac 64, Siemens Healthcare, Erlangen, Germany), respectively. For DynaCT, radiation exposure data with automatic exposure control were obtained from scanning of head, chest and abdomen. For MSCT, scanning protocols for head, chest, and abdomen were examined under conventional exposure conditions. Effective doses were calculated from LiF-TLD measurements according to ICRP103. A Catphan phantom (Phantom Lab, USA) was used to evaluate the spatial resolution and low contrast detectability of DynaCT and MSCT. Results: The effective doses for DynaCT from head, chest and abdomen scanning were 1.18, 7.32, 7.48 mSv (20 s scan) and 0.85, 6.01, 7.04 mSv (8 s scan); the effective doses for MSCT from head, chest and abdomen scanning were 3.33, 7.62 and 8.42 mSv (MSCT1), and 1.89, 7.52, 8.23 mSv (MSCT2). Significant difference between the organ doses from DynaCT and from MSCT (p<.05) was shown. The spatial resolution of 12 lp/cm was achieved and it was able to recognize a 3 mm low contrast object at 0.5% contrast level in DynaCT, which was on the same level as in the MSCT images. Conclusion: The phantom study indicates that DynaCT applies significantly less dose to patient and achieves similar spatial resolution and low contrast detectability to standard diagnostic MSCT. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
基金:
IAEA Research Contract(No.16155/R0)
the National Natural Sciences Foundation of China(NSFC)(Grant No. 30870751)
Beijing Municipal Health Bureau(Grant No. 2009-3-57)
第一作者机构:[a]Department of Biomedical Engineering, Xuanwu Hospital of Capital Medical University, No. 45 Changchun Street, Beijing 100053, PR China
通讯作者:
通讯机构:[a]Department of Biomedical Engineering, Xuanwu Hospital of Capital Medical University, No. 45 Changchun Street, Beijing 100053, PR China
推荐引用方式(GB/T 7714):
Mei Bai,Bin Liu,Hongqiu Mu,et al.The comparison of radiation dose between C-arm flat-detector CT (DynaCT) and multi-slice CT (MSCT): A phantom study[J].EUROPEAN JOURNAL OF RADIOLOGY.2012,81(11):3577-3580.doi:10.1016/j.ejrad.2011.09.006.
APA:
Mei Bai,Bin Liu,Hongqiu Mu,Xianghua Liu&Yuan Jiang.(2012).The comparison of radiation dose between C-arm flat-detector CT (DynaCT) and multi-slice CT (MSCT): A phantom study.EUROPEAN JOURNAL OF RADIOLOGY,81,(11)
MLA:
Mei Bai,et al."The comparison of radiation dose between C-arm flat-detector CT (DynaCT) and multi-slice CT (MSCT): A phantom study".EUROPEAN JOURNAL OF RADIOLOGY 81..11(2012):3577-3580