机构:[1]Department of Vascular Surgery,XuanWu Hospital, Capital Medical University, Changchun Street 45#, Beijing 100053血管外科首都医科大学宣武医院[2]School of Materials Science & Engineering,Beijing Institute of Technology, Beijing, People’s Republic of China.
Purpose: To evaluate using in-vitro and in-vivo models the feasibility and capture efficiency of a new self-convertible inferior vena cava filter (SCF), equipped with a biodegradable self-converting switch. Materials and Methods: Capture rates were tested in an in-vitro flow model for simulated supine and upright positions with clot diameters of 3 mm and 5 mm and tube diameters of 22 mm, 25 mm, and 28 mm. In the in-vivo study, five filters were implanted in five adult dogs. Venography was performed after the procedure every 2 weeks until filter conversion. Results: All filters were successfully implanted and completely converted with a mean trapping efficiency of 75.5% in the in-vivo study. The SCF was most efficient at 92% in the upright orientation with 5-mm clots and a 22-mm caval diameter. All five filters exhibited successful delivery and conversion in vitro. The SCFs were manually manufactured without barbs or hooks, and because of this feature, migration occurred. Conclusions: The SCF is feasible and highly efficient and converts itself successfully. Evaluation is planned of future prototypes with appropriate modifications for risk of migration of the filter.
基金:
National Natural Science Foundation of China [30972944, 30840077]
基金编号:3097294430840077
语种:
外文
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2010]版:
大类|4 区医学
小类|3 区核医学4 区外周血管病
最新[2023]版:
大类|3 区医学
小类|3 区外周血管病3 区核医学
JCR分区:
出版当年[2009]版:
Q2RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGINGQ3PERIPHERAL VASCULAR DISEASE
最新[2023]版:
Q2PERIPHERAL VASCULAR DISEASEQ2RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
第一作者机构:[1]Department of Vascular Surgery,XuanWu Hospital, Capital Medical University, Changchun Street 45#, Beijing 100053
通讯作者:
通讯机构:[1]Department of Vascular Surgery,XuanWu Hospital, Capital Medical University, Changchun Street 45#, Beijing 100053
推荐引用方式(GB/T 7714):
XiXiang Gao,Jian Zhang,Bing Chen,et al.A New Self-Convertible Inferior Vena Cava Filter: Experimental In-vitro and In-vivo Evaluation[J].JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY.2011,22(6):829-834.doi:10.1016/j.jvir.2011.02.018.
APA:
XiXiang Gao,Jian Zhang,Bing Chen,HengXi Yu,JianXin Li...&Jian Han.(2011).A New Self-Convertible Inferior Vena Cava Filter: Experimental In-vitro and In-vivo Evaluation.JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY,22,(6)
MLA:
XiXiang Gao,et al."A New Self-Convertible Inferior Vena Cava Filter: Experimental In-vitro and In-vivo Evaluation".JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY 22..6(2011):829-834