Objectives: The goal of this work was to reduce the scan time of contrast-enhanced whole-heart coronary magnetic resonance angiography (MRA) by using a gradient echo interleaved echo planar imaging (GRE-EPI) sequence at 3 T field strength. Materials and Methods: A GRE-EPI sequence was optimized to acquire contrast-enhanced whole-heart coronary MRA at 3 T. First-order phase correction was used for alignment of the odd and even echoes in the GRE-EPI echo train. Single and dual reference scan techniques for estimation of the linear phase correction parameters were evaluated using both phantom and volunteer studies. The GRE-EPI readout was combined with parallel imaging for a further reduction in scan time. To avoid image distortions, calibration signals for coil sensitivity estimation were acquired in a separate low resolution GRE scan before the whole-heart GRE-EPI scan. Eight healthy volunteers were scanned with the optimized contrast-enhanced GRE-EPI sequence. GRE-EPI images were acquired during slow infusion (0.3 mL/s) of 0.1 mmol/kg body weight of Gd-BOPTA. For comparison purposes, the same 8 volunteers were scanned again in a separate scan session using a traditional GRE sequence with double the dose (0.2 mmol/kg body weight) of the same contrast agent with the same injection rate. The contrast-enhanced GRE-EPI and contrast-enhanced GRE techniques were compared in terms of relative signal-to-noise ratio (rSNR), relative contrast-to-noise ratio (rCNR), image quality scores, and visualized vessel lengths. Results: Both, phantom and volunteer studies demonstrated that the dual reference scan phase correction technique was a key step for obtaining satisfactory image quality using GRE-EPI at 3 T. Whole-heart coronary MRA with a spatial resolution of 1.0 x 1.0 x 2.0 mm(3) was acquired with the GRE-EPI sequence in an average scan time of 2.5 +/- 0.6 minutes, compared with 8.6 +/- 2.7 minutes for the GRE technique. The GRE-EPI technique had lower rCNR compared with the GRE sequence. The image quality and coronary artery visualization with the GRE-EPI technique were adequate, and there was no statistically significant difference in the image quality scores, rSNR, and visualized coronary artery lengths between the GRE-EPI and GRE techniques. Conclusions: Contrast-enhanced whole-heart coronary MRA using the GRE-EPI technique resulted in excellent delineation of all the major coronary arteries and compared with current GRE techniques demonstrated a factor of 2 reduction in contrast agent dose and a factor of 3 reduction in scan time.
基金:
National Institute of Health grants numbers NIBIB EB002623 and NHLBI HL38698; Siemens Medical Solutions USA, Inc, Malvern, PA;
National Natural Science Foundation of China grant numbers 30828009 and 30900355; Captain and Mrs. Roberts Fellowship.
第一作者机构:[1]Department of Radiology and Biomedical Engineering, Northwestern University, Chicago, IL
共同第一作者:
通讯作者:
通讯机构:[*]737 N. Michigan Ave, Suite 1600, Chicago, IL 60611.
推荐引用方式(GB/T 7714):
Himanshu Bhat,Qi Yang,Sven Zuehlsdorff,et al.Contrast-Enhanced Whole-Heart Coronary Magnetic Resonance Angiography at 3 T Using Interleaved Echo Planar Imaging[J].INVESTIGATIVE RADIOLOGY.2010,45(8):458-464.doi:10.1097/RLI.0b013e3181d8df32.
APA:
Himanshu Bhat,Qi Yang,Sven Zuehlsdorff,Kuncheng Li&Debiao Li.(2010).Contrast-Enhanced Whole-Heart Coronary Magnetic Resonance Angiography at 3 T Using Interleaved Echo Planar Imaging.INVESTIGATIVE RADIOLOGY,45,(8)
MLA:
Himanshu Bhat,et al."Contrast-Enhanced Whole-Heart Coronary Magnetic Resonance Angiography at 3 T Using Interleaved Echo Planar Imaging".INVESTIGATIVE RADIOLOGY 45..8(2010):458-464