当前位置: 首页 > 详情页

Contrast-Enhanced Whole-Heart Coronary Magnetic Resonance Angiography at 3.0-T A Comparative Study With X-Ray Angiography in a Single Center

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

机构: [1]Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing, China [2]Department of Radiology, Northwestern University, Chicago, Illinois [3]Siemens Medical Solutions USA, Inc., Chicago, Illinois [4]Siemens Mindit Magnetic Resonance Ltd., Shenzhen, China [5]Siemens Ltd. China, Healthcare Magnetic Resonance, Shanghai, China.
出处:
ISSN:

关键词: coronary disease magnetic resonance imaging contrast media 3 0-T

摘要:
Objectives The purpose of this study was to prospectively evaluate the diagnostic performance of 3.0-T contrast-enhanced whole-heart coronary magnetic resonance angiography (CMRA) in patients with suspected coronary artery disease (CAD). Background A slow-infusion, contrast-enhanced whole-heart CMRA approach has recently been developed at 3.0-T. The accuracy of this technique has not yet been determined among patients with suspected CAD. Methods The 3.0-T contrast-enhanced whole-heart CMRA was performed in 69 consecutive patients. An electrocardiography-triggered, navigator-gated, inversion-recovery prepared, segmented gradient-echo sequence was used to acquire isotropic whole-heart CMRA with slow infusion of 0.2 mmol/kg gadobenate dimeglumine. The diagnostic accuracy of whole-heart CMRA in detecting significant stenoses (>= 50%) was evaluated using X-ray angiography as the reference. Results The CMRA examinations were successfully completed in 62 patients. Acquisition time of whole-heart CMRA procedure was 9.0 +/- 1.9 min. The 3.0-T whole-heart CMRA correctly identified significant CAD in 32 patients and correctly ruled out CAD in 23 patients. The sensitivity, specificity, and accuracy of whole-heart CMRA for detecting significant stenoses were 91.6% (87 of 95), 83.1% (570 of 686), and 84.1% (657 of 781), respectively, on a per-segment basis. These values were 94.1% (32 of 34), 82.1% (23 of 28), and 88.7% (55 of 62), respectively, on a per-patient basis. Conclusions Contrast-enhanced whole-heart CMRA with 3.0-T allows for the accurate detection of coronary artery stenosis with high sensitivity and moderate specificity. (J Am Coll Cardiol 2009; 54: 69-76) (C) 2009 by the American College of Cardiology Foundation

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2008]版:
大类 | 1 区 医学
小类 | 1 区 心脏和心血管系统
最新[2023]版:
大类 | 1 区 医学
小类 | 1 区 心脏和心血管系统
JCR分区:
出版当年[2007]版:
Q1 CARDIAC & CARDIOVASCULAR SYSTEMS
最新[2023]版:
Q1 CARDIAC & CARDIOVASCULAR SYSTEMS

影响因子: 最新[2023版] 最新五年平均 出版当年[2007版] 出版当年五年平均 出版前一年[2006版] 出版后一年[2008版]

第一作者:
第一作者机构: [1]Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing, China
通讯作者:
通讯机构: [*]No. 45 Changchun Street, Xuanwu District, Beijing 100053, China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16461 今日访问量:0 总访问量:871 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院