机构:[1]Department of Ophthalmology, the Second Affiliated Hospital of Soochow University, Suzhou 215004, Jiangsu Province, China[2]Department of Ophthalmology, the First Affiliated Hospital of Wannan Medical College, Wuhu 241000, Anhui Province, China[3]Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, Suzhou 215021, Jiangsu Province, China
no diffusion space. The gas accumulated in the corneal stromal bed and led to hard OBL. When the canal outlet was located at the sclera, despite was impassable, the canal could accommodate partial gas and slight soft OBL occurred. When the canal outlet was located at the posterior border of the corneoscleral limbus, soft OBL was more common because some canal were partial unobstructed and could diffuse some gas. At present, the published literature preliminarily considers that OBL doesn’t influence the excimer laser ablation effect or postoperative uncorrected and corrected visual acuity[14]. But severe hard OBL can disturb eye tracking of excimer laser. Our results showed that the refractive status of the OBL eyes 2mo after surgery was more inclined to be negative, but it didn’t reach statistical difference. In summary, keeping the gas diffusing canal unobstructed is one of the key points to decrease the incidence of OBL in FS-LASIK using FS200 FSL machine. When the outlet of gas diffusing canal was located at the posterior border of the corneoscleral limbus, the high patency rate could be obtained, thus the incidence of OBL was low. Corneal astigmatism was also a independent protective factor for OBL formation. However OBL is the result of many factors, so reducing the incidence of OBL needs the development in the technological and clinical fields. ACKNOWLEDGEMENTS Foundations: Supported by the National Natural Science Fund of China in 2017 (No.81700867); the Wannan Medical College Training Fund Project of Key Scientific Research Project in 2017 (No.WK2017ZF05).
第一作者机构:[1]Department of Ophthalmology, the Second Affiliated Hospital of Soochow University, Suzhou 215004, Jiangsu Province, China[2]Department of Ophthalmology, the First Affiliated Hospital of Wannan Medical College, Wuhu 241000, Anhui Province, China
通讯作者:
通讯机构:[3]Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, Suzhou 215021, Jiangsu Province, China
推荐引用方式(GB/T 7714):
Cheng-Hua Wei,Qiao-Yun Dai,Li-Xin Mei,et al.Paired eye-control study of unilateral opaque bubble layer in femtosecond laser assisted laser in situ keratomileusis[J].International Journal of Ophthalmology.2019,12(4):654-659.doi:10.18240/ijo.2019.04.21.
APA:
Cheng-Hua Wei,Qiao-Yun Dai,Li-Xin Mei,Yao Ge,Peng-Fei Zhang&E Song.(2019).Paired eye-control study of unilateral opaque bubble layer in femtosecond laser assisted laser in situ keratomileusis.International Journal of Ophthalmology,12,(4)
MLA:
Cheng-Hua Wei,et al."Paired eye-control study of unilateral opaque bubble layer in femtosecond laser assisted laser in situ keratomileusis".International Journal of Ophthalmology 12..4(2019):654-659