Comparison of clinical features and stent placement outcomes between airway stenosis caused by primary pulmonary malignancies and that caused by primary non-pulmonary malignancies

文献详情

资源类型:

收录情况: ◇ SCIE ◇ 统计源期刊 ◇ CSCD-C ◇ 中华系列

机构: [1]Department of Respiratory Medicine, Beijing Tian Tan Hospital, Capital Medical University, Beijing 100070 China.
出处:
ISSN:

关键词: Airway obstruction Malignancy Self expandable metal stents Bronchoscopy

摘要:
Background: Primary pulmonary malignancies (PPMs) and non-pulmonary malignancies (PNPMs) may result in airway stenosis requiring stenting. This study aimed to compare and evaluate the clinical features and stent placement outcomes of airway stenosis caused by PPMs and PNPMs. Methods: A total of 141 patients with malignant airway stenosis who underwent Micro-Tech stent placements between January 2004 and October 2017 at Department of Respiratory Medicine, Beijing Tian Tan Hospital, Capital Medical University were divided into PPM (n=100) and PNPM groups (n =41). Patients' clinical features and stent placement outcomes were collected and analyzed. Chi-square test was used to compare the categorical variables, while independent- or paired-sample t test was used to compare the continuous variables. Results: There were no significant differences in age, sex, treatment history, respiratory symptoms, and incidence of obstructive pneumonia between groups. Multiple airway involvement (63.0% vs. 31.7%; chi(2) =11.459, P=0.001) and atelectasis (17.0% vs. 2.4%; chi(2) =5.536, P=0.019) were more common in the PPM group, while extraluminal obstruction (24.4% vs. 6.0%; chi(2) =8.033, P=0.005) was more common in the PNPM group. Before scenting, the American Thoracic Society Dyspnea Index (ADI) and Kamofsky Performance Scale (KPS) scores showed no significant differences between groups (all P> 0.05). After stenting, a satisfactory rate of symptom improvement was achieved in both groups (98.0% and 100.0% in the PPM and PNPM groups, respectively; chi(2) =0.016, P=0.898); ADI and KPS scores, which showed no significant differences between groups (all P > 0.05), were significantly improved in each group (all P < 0.001). Complications after stenting could be effectively managed using bronchoscopic procedures. Conclusions: Among cases of malignant airway stenosis requiring stenting, those caused by PPM are more likely to involve multiple airways and are associated with atelectasis, while those caused by PNPM are more likely to cause extraluminal obstruction. Micro-Tech stent placement has the same immediate effect in terms of improvement in respiratory symptoms and performance status for both malignant airway stenosis caused by PPM and that caused by PNPM.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2018]版:
大类 | 4 区 医学
小类 | 4 区 医学:内科
最新[2023]版:
大类 | 3 区 医学
小类 | 3 区 医学:内科
JCR分区:
出版当年[2017]版:
Q2 MEDICINE, GENERAL & INTERNAL
最新[2023]版:
Q1 MEDICINE, GENERAL & INTERNAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2017版] 出版当年五年平均 出版前一年[2016版] 出版后一年[2018版]

第一作者:
第一作者机构: [1]Department of Respiratory Medicine, Beijing Tian Tan Hospital, Capital Medical University, Beijing 100070 China.
通讯作者:
通讯机构: [1]Department of Respiratory Medicine, Beijing Tian Tan Hospital, Capital Medical University, Beijing 100070 China. [*1]Department of Respiratory Medicine, Beijing Tian Tan Hospital, Capital Medical University, Beijing 100070, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院