Angiographic contrast mechanism comparison between Simultaneous Non-contrast Angiography and intraPlaque hemorrhage (SNAP) sequence and Time of Flight (TOF) sequence for intracranial artery.

文献详情

资源类型:

收录情况: ◇ SCIE

机构: [1]Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China [2]Vascular Imaging Laboratory, Department of Radiology, University of Washington, Seattle, Washington, USA [3]Department of Interventional Neuroradiology, Beijing Neuroradiology Institute and Beijing TianTan Hospital, Capital Medical University, Beijing, China [4]Beijing Institute of Brain Disorders, Capital Medical University, Beijing, China [5]Collaborative Innovation Center for Brain Disorders, Capital Medical University, Beijing, China
出处:
ISSN:

摘要:
To theoretically compare the MR angiography (MRA) contrast mechanism of Time of Flight (TOF) and Simultaneous Non-contrast Angiography and intraPlaque hemorrhage (SNAP) for intracranial artery imaging with in-vivo validation. The contrast ratio (CR) of SNAP and TOF was simulated under different blood velocities and travel distance that the blood had flown through. The CR and the slope of CR with respect to blood velocity of SNAP and TOF were compared in theoretical simulation. Two healthy subjects (a 60 years old female and a 29 years old male) were imaged on a 3 T MR scanner with SNAP, TOF and phase contrast (PC) images as the validation set. The measured CR from the images in validation set was compared with the theoretically simulated CR by Person's correlation coefficient. The ratio of CR difference to velocity difference in the validation set was compared between TOF and SNAP with Student's t-test. Thirty patients (21 males, age: 48 ± 13.8 years) with carotid artery atherosclerotic plaque were imaged with both TOF and SNAP as the comparison test. Between TOF and SNAP, the CR and total artery length were compared with Student's t-test, and the prevalence of stenosis was compared with Cohen's kappa in comparison test. The theoretically simulated CR was significantly correlated with in-vivo measured CR from the validation set for TOF (p < 0.001) and SNAP (p < 0.001). The simulation revealed that the CR of SNAP was higher than that of TOF when the blood velocity and travel distance were within the range to have effective MRA contrast. Similarly, the in-vivo comparison test showed that SNAP had higher CR (p < 0.001 for all tested intracranial arteries) and longer total artery length (1.4 ± 0.4 m vs 1.2 ± 0.2 m, p < 0.001) than TOF. The stenosis detection performance was similar between TOF and SNAP (Cohen's kappa 0.72; 95% confidence interval: 0.51-0.93). Moreover, compared with TOF, SNAP showed higher slope of CR with respect to velocity in simulation (0.06 ± 0.02 s/cm vs 0.02 ± 0.05 s/cm, p < 0.001), and higher ratio of CR difference to velocity difference in validation test (0.47 ± 0.38 s/cm vs 0.19 ± 0.38 s/cm, p = 0.001). Compared with TOF, the SNAP shows better performance to visualize distal intracranial artery and worse performance to visualize ICA, and is more sensitive to blood velocity. Copyright © 2019. Published by Elsevier Inc.

语种:
PubmedID:
中科院(CAS)分区:
出版当年[2018]版:
大类 | 3 区 医学
小类 | 3 区 核医学
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 核医学
JCR分区:
出版当年[2017]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2017版] 出版当年五年平均 出版前一年[2016版] 出版后一年[2018版]

第一作者:
第一作者机构: [1]Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China
通讯作者:
通讯机构: [1]Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China [*1]Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China [*2]Center for Biomedical Imaging Research #110, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院