Intracranial pressure responsiveness to positive end-expiratory pressure is influenced by chest wall elastance: a physiological study in patients with aneurysmal subarachnoid hemorrhage
机构:[1]Department of Critical Care Medicine, Beijing Tiantan Hospital, Capital Medical University, No 6, Tiantan Xili, Dongcheng District, Beijing, China.诊疗科室重症医学科(ICU)首都医科大学附属天坛医院[2]Surgical Intensive Care Unit, Fujian Provincial Clinical College, Fujian Medical University, Fuzhou, Fujian, China.
Background: Respiratory system elastance (ERS) is an important determinant of the responsiveness of intracranial pressure (ICP) to positive end-expiratory pressure (PEEP). However, lung elastance (EL) and chest wall elastance (ECW) were not differentiated in previous studies. We tested the hypothesis that patients with high ECW or a high ECW/ERS ratio have greater ICP responsiveness to PEEP. Methods: An esophageal balloon catheter was placed to measure esophageal pressure. PEEP was increased from 5 to 15 cmH2O. Airway pressure and esophageal pressure were measured and EL, ECW and ERS were calculated at the two PEEP levels. Patients were classified into either an ICP responder group or a non-responder group based on whether the change of ICP after PEEP adjustment was greater than or less than the median of the overall study population. Results: The magnitude of the increase in esophageal pressure (median [interquartile range]) at end-expiratory occlusion was significantly increased in the responder group compared with that in the non-responder group (4.1 [2.7-4.1] versus 2.7 [0.0-2.7] cmH(2)O, p = 0.033) after PEEP adjustment. ECW and the ECW/ERS ratio were significantly higher in ICP responders than in non-responders at both low PEEP (p = 0.021 and 0.017) and high PEEP (p = 0.011 and 0.025) levels. No significant differences in ERS and EL were noted between the two groups at both PEEP levels. Conclusions: Patients with greater ICP responsiveness to increased PEEP exhibit higher ECW and a higher ECW/ERS ratio, suggesting the importance of ECW monitoring.
基金:
Beijing Municipal Administration of Hospital [ZYLX201502]
第一作者机构:[1]Department of Critical Care Medicine, Beijing Tiantan Hospital, Capital Medical University, No 6, Tiantan Xili, Dongcheng District, Beijing, China.[2]Surgical Intensive Care Unit, Fujian Provincial Clinical College, Fujian Medical University, Fuzhou, Fujian, China.
通讯作者:
通讯机构:[1]Department of Critical Care Medicine, Beijing Tiantan Hospital, Capital Medical University, No 6, Tiantan Xili, Dongcheng District, Beijing, China.
推荐引用方式(GB/T 7714):
Chen Han,Chen Kai,Xu Jing-Qing,et al.Intracranial pressure responsiveness to positive end-expiratory pressure is influenced by chest wall elastance: a physiological study in patients with aneurysmal subarachnoid hemorrhage[J].BMC NEUROLOGY.2018,18(1):-.doi:10.1186/s12883-018-1132-2.
APA:
Chen, Han,Chen, Kai,Xu, Jing-Qing,Zhang, Ying-Rui,Yu, Rong-Guo&Zhou, Jian-Xin.(2018).Intracranial pressure responsiveness to positive end-expiratory pressure is influenced by chest wall elastance: a physiological study in patients with aneurysmal subarachnoid hemorrhage.BMC NEUROLOGY,18,(1)
MLA:
Chen, Han,et al."Intracranial pressure responsiveness to positive end-expiratory pressure is influenced by chest wall elastance: a physiological study in patients with aneurysmal subarachnoid hemorrhage".BMC NEUROLOGY 18..1(2018):-