当前位置: 首页 > 详情页

Biomechanical Analysis of Porous Additive Manufactured Cages for Lateral Lumbar Interbody Fusion: A Finite Element Analysis.

文献详情

资源类型:
机构: [1]Department of Mechanical Engineering, Tsinghua University, Beijing [2]Biomechanics and Biotechnology Lab, Research Institute of Tsinghua University in Shenzhen, Shenzhen [3]Naton Science and Technology Group, Beijing, China [4]Spine Pain Begone Clinic, San Antonio, TX, USA
出处:
ISSN:

摘要:
A porous additive manufactured (AM) cage may provide stability similar to that of traditional solid cages and may be beneficial to bone ingrowth. The biomechanical influence of various porous cages on stability, subsidence, stresses in cage, and facet contact force has not been fully described. The purpose of this study was to verify biomechanical effects of porous AM cages. The surgical finite element models with various cages were constructed. The partially porous titanium (PPT) cages and fully porous titanium (FPT) cages were applied. The mechanical parameters of porous materials were obtained by mechanical test. Then the porous AM cages were compared with solid titanium (TI) cage and solid polyetheretherketone (PEEK) cage. The 4 motion modes were simulated. Range of motion (ROM), cage stress, end plate stress, and facet joint force (FJF) were compared. For all the surgical models, ROM decreased by >90%. Compared with TI and PPT cages, PEEK and FPT cages substantially reduced the maximum stresses in cage and end plate in all motion modes. Compared with PEEK cages, the stresses in cage and end plate for FPT cages decreased, whereas the ROM increased. Comparing FPT cages, the stresses in cage and end plate decreased with increasing porosity, whereas ROM increased with increasing porosity. After interbody fusion, FJF was substantially reduced in all motion modes except for flexion. Fully porous cages may offer an alternative to solid PEEK cages in lateral lumbar interbody fusion. However, it may be prudent to further increase the porosity of the cage. Copyright © 2017 Elsevier Inc. All rights reserved.

语种:
PubmedID:
中科院(CAS)分区:
出版当年[2017]版:
大类 | 3 区 医学
小类 | 3 区 临床神经病学 3 区 外科
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 临床神经病学 4 区 外科
第一作者:
第一作者机构: [1]Department of Mechanical Engineering, Tsinghua University, Beijing [2]Biomechanics and Biotechnology Lab, Research Institute of Tsinghua University in Shenzhen, Shenzhen
通讯作者:
通讯机构: [1]Department of Mechanical Engineering, Tsinghua University, Beijing [2]Biomechanics and Biotechnology Lab, Research Institute of Tsinghua University in Shenzhen, Shenzhen
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16461 今日访问量:0 总访问量:871 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院