Hybrid Constructs for Performing Three-level Hybrid Surgery: A Finite Element Study.

文献详情

资源类型:
机构: [1]State Key Laboratory of Tribology,Tsinghua University, Beijing [2]Department of Mechanical Engineering, Tsinghua University, Beijing [3]Biomechanics and Biotechnology Lab, Research Institute of Tsinghua University in Shenzhen, Shenzhen, P. R. China
出处:
ISSN:

摘要:
To systematically investigate the effect of 3-level hybrid constructs on the cervical spine biomechanics based on a validated model of the C3-C7 segments. Three hybrid constructs with 2 U-shaped dynamic cervical implants and 1 cage were simulated. The 3 constructs were 1) Cage-U-U (cage implanted at the C3-C4 level and U-shaped dynamic cervical implants implanted at the C4-C5 and C5-C6 levels), 2) U-Cage-U, and 3) U-U-Cage. Biomechanical parameters including moments, cervical motions, and stresses in the facet and implants were analyzed in flexion and extension. The flexion and extension motions at artificial cervical disc replacement levels increased for all hybrid constructs when compared with those of intact model. However, the maximum increase was 52% with U-U-Cage model. At the unoperated adjacent level, the maximum motion increase in extension was 23% with the U-U-Cage model. Also, the U-U-Cage and U-Cage-U model generated more than 40% increase in terms of flexion motion at the adjacent level. The facet stress at the adjacent level increased by 28%, 20%, and 39% with the Cage-U-U, U-Cage-U, and U-U-Cage models, respectively. The moments required to reach the same motion as the intact model were significantly increased. The study showed that the U-U-Cage model lead to more compensation in terms of motion and facet stress. Furthermore, the present results imply that when conducting the hybrid surgery, the segmental motions should be taken into account. Performing anterior cervical discectomy and fusion at the level whose motion is relatively small may decrease the compensation required at the adjacent level. Copyright © 2018 Elsevier Inc. All rights reserved.

语种:
PubmedID:
中科院(CAS)分区:
出版当年[2017]版:
大类 | 3 区 医学
小类 | 3 区 临床神经病学 3 区 外科
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 临床神经病学 4 区 外科
第一作者:
第一作者机构: [1]State Key Laboratory of Tribology,Tsinghua University, Beijing [2]Department of Mechanical Engineering, Tsinghua University, Beijing
通讯作者:
通讯机构: [2]Department of Mechanical Engineering, Tsinghua University, Beijing [3]Biomechanics and Biotechnology Lab, Research Institute of Tsinghua University in Shenzhen, Shenzhen, P. R. China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院