当前位置: 首页 > 详情页

Clinical feature and waveform in infantile nystagmus syndrome in children with FRMD7 gene mutations

文献详情

资源类型:

收录情况: ◇ SCIE ◇ CSCD-C

机构: [1]Capital Med Univ, Beijing Childrens Hosp, Dept Ophthalmol, Natl Ctr Childrens Hlth, Beijing 100045, Peoples R China; [2]Capital Med Univ, Beijing Pediat Res Inst, Beijing Childrens Hosp, Natl Ctr Childrens Hlth, Beijing 100045, Peoples R China; [3]Capital Med Univ, Beijing Tongren Hosp, Dept Dermatol, Beijing 100730, Peoples R China
出处:
ISSN:

关键词: infantile nystagmus FRMD7 gene mutation waveform vision stereopsis

摘要:
Infant nystagmus sydrome presents as involuntary eye movement disorder and can affect seriously ocular function. We performed a retrospective study of clinical data and FRMD7 genetic test results in 12 cases of infantile nystagmus syndrome to correlate waveform, stereopsis, and visual acuity. The patients (age 6.40 +/- 2.67 years) had FRMD7 mutations as follows: missense in eight cases, shear in two cases, frameshift in one case, and non-frameshift in one case. Horizontal jerk waveform was observed in six cases, versus horizontal pendulum in five cases and dual jerk in one case. The uncorrected visual acuity (24 eyes) was 0.21 +/- 0.12, compared with a corrected visual acuity (24 eyes) of 0.32 +/- 0.14. All patients had simultaneous perception, versus fusion function in 10 cases (83.33%) and stereoscopic vision in seven cases (58.33%) using the synoptophore. Eleven cases (91.67%) detected the stereo fly, compared with five cases (41.67%) for stereoscopic circles and seven cases (58.33%) for stereoscopic animals by Titmus test. Stereoscopic vision using the synoptophore did not correlate with the frequency, amplitude, or intensity of nystagmus or with corrected binocular visual acuity. The infantile nystagmus syndrome with FRMD7 mutations in our cases was caused primarily de novo and missense mutations. Visual acuity and binocular visual function were significant impaired, and the waveform was generally horizontal jerk. Also, an infrared videonystagmogram can record the frequency, amplitude, and intensity of nystagmus accurately.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2016]版:
大类 | 4 区 生物
小类 | 3 区 生物学
最新[2023]版:
大类 | 2 区 生物学
小类 | 2 区 生物学
JCR分区:
出版当年[2015]版:
Q2 BIOLOGY
最新[2023]版:
Q1 BIOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2015版] 出版当年五年平均 出版前一年[2014版] 出版后一年[2016版]

第一作者:
第一作者机构: [1]Capital Med Univ, Beijing Childrens Hosp, Dept Ophthalmol, Natl Ctr Childrens Hlth, Beijing 100045, Peoples R China;
通讯作者:
通讯机构: [1]Capital Med Univ, Beijing Childrens Hosp, Dept Ophthalmol, Natl Ctr Childrens Hlth, Beijing 100045, Peoples R China;
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院