机构:[1]Capital Med Univ, Beijing Tiantan Hosp, Dept Crit Care Med, 6 Tiantan Xili, Beijing 100050, Peoples R China;诊疗科室重症医学科(ICU)首都医科大学附属天坛医院[2]Fujian Med Univ, Fujian Prov Clin Coll Hosp, Fuzhou, Fujian, Peoples R China;[3]Capital Med Univ, Beijing Elect Power Hosp, Beijing, Peoples R China
Objective: To investigate the clinical feasibility of the injection test for balloon placement during oesophageal pressure measurement in patients without spontaneous breathing. Methods: The injection test was performed in 12 mechanically ventilated patients under deep sedation and paralysis. During withdrawal of the balloon from the stomach and air injection into the gastric lumen of the catheter, the presence of the injection test wave in the balloon pressure tracing indicated that the whole balloon was positioned above the lower oesophageal sphincter (LES). The positive pressure occlusion test was performed at different balloon positions. Results: In each patient, the injection test wave appeared at a distinct balloon depth, with a mean +/- standard deviation of 41.9 +/- 3.3 cm and range from 37 cm to 47 cm. The optimal ratio of changes in the balloon and airway pressure (0.8-1.2) during the positive pressure occlusion test was obtained when the balloon was located 5 cm and 10 cm above the LES in nine (75%) and three (25%) patients, respectively. Conclusions: The injection test is feasible for identification of the whole balloon position above the LES during passive ventilation. The middle third of the oesophagus might be the optimal balloon position.
基金:
Beijing Municipal Administration of Hospital [ZYLX201502]
语种:
外文
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2016]版:
大类|4 区医学
小类|4 区医学:研究与实验4 区药学
最新[2023]版:
大类|4 区医学
小类|4 区医学:研究与实验4 区药学
JCR分区:
出版当年[2015]版:
Q3MEDICINE, RESEARCH & EXPERIMENTALQ4PHARMACOLOGY & PHARMACY
最新[2023]版:
Q4MEDICINE, RESEARCH & EXPERIMENTALQ4PHARMACOLOGY & PHARMACY
第一作者机构:[1]Capital Med Univ, Beijing Tiantan Hosp, Dept Crit Care Med, 6 Tiantan Xili, Beijing 100050, Peoples R China;[2]Fujian Med Univ, Fujian Prov Clin Coll Hosp, Fuzhou, Fujian, Peoples R China;
通讯作者:
通讯机构:[1]Capital Med Univ, Beijing Tiantan Hosp, Dept Crit Care Med, 6 Tiantan Xili, Beijing 100050, Peoples R China;
推荐引用方式(GB/T 7714):
Chen Han,Yang Yan-Lin,Xu Ming,et al.Use of the injection test to indicate the oesophageal balloon position in patients without spontaneous breathing: a clinical feasibility study[J].JOURNAL OF INTERNATIONAL MEDICAL RESEARCH.2017,45(1):320-331.doi:10.1177/0300060516679776.
APA:
Chen, Han,Yang, Yan-Lin,Xu, Ming,Shi, Zhong-Hua,He, Xuan...&Zhou, Jian-Xin.(2017).Use of the injection test to indicate the oesophageal balloon position in patients without spontaneous breathing: a clinical feasibility study.JOURNAL OF INTERNATIONAL MEDICAL RESEARCH,45,(1)
MLA:
Chen, Han,et al."Use of the injection test to indicate the oesophageal balloon position in patients without spontaneous breathing: a clinical feasibility study".JOURNAL OF INTERNATIONAL MEDICAL RESEARCH 45..1(2017):320-331