Hemodynamic alterations after stent implantation in 15 cases of intracranial aneurysm

文献详情

资源类型:

收录情况: ◇ SCIE

机构: [1]Capital Med Univ, Beijing Neurosurg Inst, Dept Intervent Neuroradiol, TiantanXili 6, Beijing 100050, Peoples R China; [2]Capital Med Univ, Beijing Tian Tan Hosp, TiantanXili 6, Beijing 100050, Peoples R China; [3]SUNY Buffalo, Toshiba Stroke & Vasc Res Ctr, Buffalo, NY 14260 USA; [4]SUNY Buffalo, Dept Mech & Aerosp Engn, Buffalo, NY 14260 USA; [5]Fudan Univ, Dept Mech & Engn Sci, Shanghai 200433, Peoples R China; [6]SUNY Buffalo, Dept Neurosurg, Buffalo, NY 14260 USA; [7]SUNY Buffalo, Dept Radiol, Buffalo, NY 14260 USA
出处:
ISSN:

关键词: Intracranial aneurysm Stent Hemodynamics Velocity Wall shear stress Pressure

摘要:
Stent-assisted coiling technology has been widely used in the treatment of intracranial aneurysms. In the current study, we investigated the intra-aneurysmal hemodynamic alterations after stent implantation and their association with the aneurysm location. We first retrospectively studied 15 aneurysm cases [8 internal carotid artery-ophthalmic artery (ICA-OphA) aneurysms and 7 posterior communicating artery (PcoA) aneurysms] treated with Enterprise stents and coils. Then, based on the patient-specific geometries before and after stenting, we built virtual stenting computational fluid dynamics (CFD) simulation models. Before and after the stent deployment, the average wall shear stress (WSS) on the aneurysmal sac at systolic peak changed from 7.04 Pa (4.14 Pa, 15.77 Pa) to 6.04 Pa (3.86 Pa, 11.13 Pa), P = 0.001; the spatially averaged flow velocity in the perpendicular plane of the aneurysm dropped from 0.5 m/s (0.28 m/s, 0.7 m/s) to 0.33 m/s (0.25 m/s, 0.49 m/s), P = 0.001, respectively. Post stent implantation, the WSS in ICA-OphA aneurysms and PcoA aneurysms decreased by 14.4 % (P = 0.012) and 16.6 % (P = 0.018), respectively, and the flow velocity also reduced by 10.3 % (P = 0.029) and 10.5 % (P = 0.013), respectively. Changes in the WSS, flow velocity, and pressure were not significantly different between ICA-OphA and PcoA aneurysms (P > 0.05). Stent implantation did not significantly change the peak systolic pressure in either aneurysm type. After the stent implantation, both the intra-aneurysmal flow velocity and WSS decreased independently of aneurysm type (ICA-OphA and PcoA). Little change was observed in peak systolic pressure.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2015]版:
大类 | 4 区 医学
小类 | 3 区 外科 4 区 临床神经病学
最新[2023]版:
大类 | 3 区 医学
小类 | 3 区 外科 4 区 临床神经病学
JCR分区:
出版当年[2014]版:
Q2 SURGERY Q3 CLINICAL NEUROLOGY
最新[2023]版:
Q2 SURGERY Q3 CLINICAL NEUROLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2014版] 出版当年五年平均 出版前一年[2013版] 出版后一年[2015版]

第一作者:
第一作者机构: [1]Capital Med Univ, Beijing Neurosurg Inst, Dept Intervent Neuroradiol, TiantanXili 6, Beijing 100050, Peoples R China; [2]Capital Med Univ, Beijing Tian Tan Hosp, TiantanXili 6, Beijing 100050, Peoples R China;
通讯作者:
通讯机构: [1]Capital Med Univ, Beijing Neurosurg Inst, Dept Intervent Neuroradiol, TiantanXili 6, Beijing 100050, Peoples R China; [2]Capital Med Univ, Beijing Tian Tan Hosp, TiantanXili 6, Beijing 100050, Peoples R China;
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院