当前位置: 首页 > 详情页

Effect of hemodynamics on outcome of subtotally occluded paraclinoid aneurysms after stent-assisted coil embolization

文献详情

资源类型:

收录情况: ◇ SCIE

机构: [1]Capital Med Univ, Beijing Neurosurg Inst, Dept Intervent Neuroradiol, TiantanXili 6, Beijing 100050, Peoples R China; [2]Capital Med Univ, Beijing Tiantan Hosp, TiantanXili 6, Beijing 100050, Peoples R China; [3]SUNY Buffalo, Toshiba Stroke & Vasc Res Ctr, Buffalo, NY USA; [4]SUNY Buffalo, Dept Mech & Aerosp Engn, Buffalo, NY USA; [5]Fudan Univ, Dept Mech & Engn Sci, Shanghai, Peoples R China; [6]SUNY Buffalo, Dept Neurosurg, Buffalo, NY USA; [7]SUNY Buffalo, Dept Radiol, Buffalo, NY USA
出处:
ISSN:

关键词: Aneurysm Blood Flow Stent

摘要:
Background Endovascular treatment of paraclinoid aneurysms is preferred in clinical practice. Flow alterations caused by stents and coils may affect treatment outcome. Objective To assess hemodynamic changes following stent-assisted coil embolization (SACE) in subtotally embolized paraclinoid aneurysms with residual necks that were predisposed to recanalization. Methods We studied 27 paraclinoid aneurysms (seven recanalized and 20 stable) treated with coils and Enterprise stents. Computational fluid dynamic simulations were performed on patient-specific aneurysm geometries using virtual stenting and porous media technology. Results After stent placement in 27 cases, aneurysm flow velocity decreased significantly, the reduction gradually increasing from the neck plane (11.9%), to the residual neck (12.3%), to the aneurysm dome (16.3%). Subsequent coil embolization was performed after stent placement and the hemodynamic factors decreased further and significantly at all aneurysm regions except the neck plane. In a comparison of recanalized and stable cases, univariate analysis showed no significant differences in any parameter before treatment. After stent-assisted coiling, only the reduction in area-averaged velocity at the neck plane differed significantly between recanalized (8.1%) and stable cases (20.5%) (p=0.016). Conclusions Aneurysm flow velocity can be significantly decreased by stent placement and coil embolization. However, hemodynamics at the aneurysm neck plane is less sensitive to coils. Significant reduction in flow velocity at the neck plane may be an important factor in preventing recanalization of paraclinoid aneurysms after subtotal SACE.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2015]版:
大类 | 3 区 医学
小类 | 3 区 外科 4 区 神经成像
最新[2023]版:
大类 | 1 区 医学
小类 | 1 区 神经成像 1 区 外科
JCR分区:
出版当年[2014]版:
Q1 SURGERY Q2 NEUROIMAGING
最新[2023]版:
Q1 NEUROIMAGING Q1 SURGERY

影响因子: 最新[2023版] 最新五年平均 出版当年[2014版] 出版当年五年平均 出版前一年[2013版] 出版后一年[2015版]

第一作者:
第一作者机构: [1]Capital Med Univ, Beijing Neurosurg Inst, Dept Intervent Neuroradiol, TiantanXili 6, Beijing 100050, Peoples R China; [2]Capital Med Univ, Beijing Tiantan Hosp, TiantanXili 6, Beijing 100050, Peoples R China;
通讯作者:
通讯机构: [1]Capital Med Univ, Beijing Neurosurg Inst, Dept Intervent Neuroradiol, TiantanXili 6, Beijing 100050, Peoples R China; [2]Capital Med Univ, Beijing Tiantan Hosp, TiantanXili 6, Beijing 100050, Peoples R China;
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院