当前位置: 首页 > 详情页

COLOR DOPPLER ULTRASOUND IN DIAGNOSIS AND ASSESSMENT OF CAROTID BODY TUMORS: COMPARISON WITH COMPUTED TOMOGRAPHY ANGIOGRAPHY

文献详情

资源类型:

收录情况: ◇ SCIE ◇ EI

机构: [1]Capital Med Univ, Beijing Tiantan Hosp, Dept Ultrasound, Beijing, Peoples R China; [2]Guangdong Med Coll, Affiliated Hosp, Dept Ultrasound, Zhanjiang, Peoples R China; [3]Guangdong Med Coll, Affiliated Hosp, Dept Radiol, Zhanjiang, Peoples R China; [4]6 Tiantan Xili, Beijing 100050, Peoples R China
出处:
ISSN:

关键词: Carotid body tumor Diagnosis Color Doppler ultrasound Computed tomography angiography

摘要:
A carotid body tumor (CBT) is a rare, non-chromaffin paraganglioma, and its diagnosis mainly depends on imaging modalities. The aim of this study was to investigate the ability of color Doppler ultrasound (CDU) in the diagnosis and assessment of CBT based on computed tomography (CT). We retrospectively reviewed the CDU and CT features of 49 consecutive CBTs and 23 schwannomas from 67 patients and compared these findings with surgical resection specimens. The mean size of CBT lesions on ultrasound scans and CT angiography (CTA) was 3.24 cm +/- 0.82 cm (range, 1.6- 5.2 cm) and 3.84 cm +/- 1.08 cm (range, 1.8-6.8 cm), respectively, which had statistically significant difference (t = 9.815, p = 0.000). The vascularity of CBT lesions was richer than that of schwannoma lesions (p < 0.05). Intra-lesional vascularities feeding CBT mostly arose from the external carotid artery and had spectrum characteristics including low velocity and resistance. Peak systolic velocity (PSV) and resistance index (RI) of the vasa vasorum were 39.8 cm/s +/- 19.8 cm/s and 0.54 +/- 0.06, respectively. There was the correlation between CTA and CDU in identifying Shamblin type I CBT lesions, while CTA technique was superior for CDU, identifying Shamblin type II and III CBT lesions. Accuracy, specificity and sensitivity of CDU in diagnosing CBTs were 87.5% (63 of 72), 82.6% (19 of 23) and 89.8% (44 of 49), respectively. Both accuracy and sensitivity of CTA in diagnosing CBTs were 100%. CDU can be useful for assessment of Shamblin's type and intralesional blood flow of CBTs before its metastases, while CT imaging can reveal the relationship between lesions and adjacent arteries, as well as the involvement of the skull base. CDU combined with CT imaging can be used as an optimal detection modality for the assessment and management of CBT. (E-mail: ttyyus@ sina. com) (C) 2016 World Federation for Ultrasound in Medicine & Biology.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2015]版:
大类 | 3 区 医学
小类 | 2 区 声学 3 区 核医学
最新[2023]版:
大类 | 3 区 医学
小类 | 3 区 声学 3 区 核医学
JCR分区:
出版当年[2014]版:
Q1 ACOUSTICS Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Q2 ACOUSTICS

影响因子: 最新[2023版] 最新五年平均 出版当年[2014版] 出版当年五年平均 出版前一年[2013版] 出版后一年[2015版]

第一作者:
第一作者机构: [1]Capital Med Univ, Beijing Tiantan Hosp, Dept Ultrasound, Beijing, Peoples R China;
通讯作者:
通讯机构: [1]Capital Med Univ, Beijing Tiantan Hosp, Dept Ultrasound, Beijing, Peoples R China; [4]6 Tiantan Xili, Beijing 100050, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院