The standard deviation of extracellular water/intracellular water is associated with all-cause mortality and technique failure in peritoneal dialysis patients
机构:[1]Capital Med Univ, Beijing Tian Tan Hosp, Dept Cardiol, 6 Tian Tan Xi Li, Beijing 100050, Peoples R China;[2]Aerosp Ctr Hosp, Dept Endocrinol, Beijing, Peoples R China;[3]Peking Univ, Hosp 3, Div Nephrol, 49 North Garden Rd, Beijing 100083, Peoples R China
The mortality rate of peritoneal dialysis (PD) patients is still high, and the predicting factors for PD patient mortality remain to be determined. This study aimed to explore the relationship between the standard deviation (SD) of extracellular water/intracellular water (E/I) and all-cause mortality and technique failure in continuous ambulatory PD (CAPD) patients. All 152 patients came from the PD Center between January 1st 2006 and December 31st 2007. Clinical data and at least five-visit E/I ratio defined by bioelectrical impedance analysis were collected. The patients were followed up till December 31st 2010. The primary outcomes were death from any cause and technique failure. Kaplan-Meier analysis and Cox proportional hazards models were used to identify risk factors for mortality and technique failure in CAPD patients. All patients were followed up for 59.6 +/- 23.0 months. The patients were divided into two groups according to their SD of E/I values: lower SD of E/I group (aecurrency sign0.126) and higher SD of E/I group (> 0.126). The patients with higher SD of E/I showed a higher all-cause mortality (log-rank chi (2) = 10.719, P = 0.001) and technique failure (log-rank chi (2) = 9.724, P = 0.002) than those with lower SD of E/I. Cox regression analysis found that SD of E/I independently predicted all-cause mortality (HR 3.551, 95 % CI 1.442-8.746, P = 0.006) and technique failure (HR 2.487, 95 % CI 1.093-5.659, P = 0.030) in CAPD patients after adjustment for confounders except when sensitive C-reactive protein was added into the model. The SD of E/I was a strong independent predictor of all-cause mortality and technique failure in CAPD patients.
基金:
Peritoneal Dialysis Center, Peking University Third Hospital; Cheung Kong Scholar ProgramMinistry of Education, China [36-1]; Ministry of Education, People's Republic of ChinaMinistry of Education, China; Beijing Municipal Science and Technology Foundation [D131100004713002]
第一作者机构:[1]Capital Med Univ, Beijing Tian Tan Hosp, Dept Cardiol, 6 Tian Tan Xi Li, Beijing 100050, Peoples R China;
通讯作者:
通讯机构:[1]Capital Med Univ, Beijing Tian Tan Hosp, Dept Cardiol, 6 Tian Tan Xi Li, Beijing 100050, Peoples R China;[3]Peking Univ, Hosp 3, Div Nephrol, 49 North Garden Rd, Beijing 100083, Peoples R China
推荐引用方式(GB/T 7714):
Tian Jun-Ping,Wang Hong,Du Feng-He,et al.The standard deviation of extracellular water/intracellular water is associated with all-cause mortality and technique failure in peritoneal dialysis patients[J].INTERNATIONAL UROLOGY AND NEPHROLOGY.2016,48(9):1547-1554.doi:10.1007/s11255-016-1371-3.
APA:
Tian, Jun-Ping,Wang, Hong,Du, Feng-He&Wang, Tao.(2016).The standard deviation of extracellular water/intracellular water is associated with all-cause mortality and technique failure in peritoneal dialysis patients.INTERNATIONAL UROLOGY AND NEPHROLOGY,48,(9)
MLA:
Tian, Jun-Ping,et al."The standard deviation of extracellular water/intracellular water is associated with all-cause mortality and technique failure in peritoneal dialysis patients".INTERNATIONAL UROLOGY AND NEPHROLOGY 48..9(2016):1547-1554