当前位置: 首页 > 详情页

The Value of syngo DynaPBV Neuro During Neuro-Interventional Hypotensive Balloon Occlusion Test.

文献详情

资源类型:
机构: [1]Department of Neurosurgery, Wuhan General Hospital of Guangzhou Military Command, PLA, 627 Wuluo Avenue, 430070, Wuhan, Hubei, PR China. [2]Neurosurgical Institute of PLA, Wuhan, PR China. [3]Department of Neurosurgery, Wuhan General Hospital of Guangzhou Military Command, PLA, 627 Wuluo Avenue, 430070, Wuhan, Hubei, PR China. mlt1937@163.com. [4]Neurosurgical Institute of PLA, Wuhan, PR China. mlt1937@163.com. [5]Department of Neuroradiology, University of Erlangen-Nuremberg, Erlangen, Germany. [6]Siemens Ltd. China, Healthcare Sector, Beijing, PR China. [7]Siemens Ltd. China, Shanghai Branch, Healthcare Sector, Shanghai, PR China. [8]Siemens AG, Healthcare Sector, Erlangen, Germany.
出处:
ISSN:

摘要:
This study explored the value of flat detector computed tomography based brain perfusion imaging in assessing patient's tolerance prior to the permanent internal carotid artery occlusion. Ten patients diagnosed with neurovascular diseases through digital subtracted angiography (DSA) were enrolled into this study. Temporary balloon occlusion test (BOT) was performed for each patient with hypotensive challenge. During the test, parametric color-coded quantitative DSA (CCQ-DSA) was generated to evaluate the venous filling symmetry on both hemispheres. In addition, cerebral blood volume (CBV) maps were acquired before and during the test. Regions of interests were defined to quantitatively extract CBV value from affected and unaffected hemispheres and calculate relative CBV (rCBV), indicating perfusion symmetry. All the patients showed good perfusion symmetry before the test with rCBV close to 1.00. During the test, good perfusion symmetry was detected in 7 patients with averaged rCBV 1.03 ± 0.06. Only short venous delay and no ischemic complications were recognized. One patient had neither neurologic deficits nor long venous delay detected, however, showed hyper-perfusion in specific regions in the CBV maps. Two patients failed to pass the test, which showed significantly low CBV value from the affected hemisphere with maximum rCBV reduction close to 45%. CBV map had in general good consistency with clinical manifestations as well as venous filling in the BOT. Besides, it may provide further evidence of hemodynamic variations and delayed ischemic complications, and thus, had a potential to reduce risks and increase treatment safety.

语种:
PubmedID:
中科院(CAS)分区:
出版当年[2014]版:
大类 | 4 区 医学
小类 | 4 区 临床神经病学 4 区 核医学
最新[2023]版:
大类 | 3 区 医学
小类 | 3 区 临床神经病学 3 区 核医学
第一作者:
第一作者机构: [1]Department of Neurosurgery, Wuhan General Hospital of Guangzhou Military Command, PLA, 627 Wuluo Avenue, 430070, Wuhan, Hubei, PR China. [2]Neurosurgical Institute of PLA, Wuhan, PR China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16461 今日访问量:0 总访问量:871 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院