当前位置: 首页 > 详情页

Correlation of measured and calculated serum osmolality during mannitol or hypertonic saline infusion in patients after craniotomy: a study protocol and statistical analysis plan for a randomised controlled trial

文献详情

资源类型:

收录情况: ◇ SCIE

机构: [1]Capital Med Univ, Beijing Tiantan Hosp, Dept Crit Care Med, Beijing, Peoples R China
出处:
ISSN:

关键词: Neurosurgery

摘要:
Introduction Brain oedema is a major complication after craniotomy. Hyperosmolar agents have been used as the medical treatment for this condition. Measurement and estimation of serum osmolality during hyperosmolar agent infusion is of clinical importance to evaluate clinical efficacy, adjust dosage and avoid side effects. However, several studies have shown that calculated serum osmolality may lead to a systematic bias compared with direct measurement. In the present study, mannitol or hypertonic saline (HS) will be used in patients after elective craniotomy. We aim to determine the accuracy of serum osmolality estimation during the application of hyperosmolar agent. Methods and analysis The study is a prospective, randomised, double-blinded, controlled, parallel-group design. Adult patients requiring the use of hyperosmolar agents for the prevention or treatment of postoperative brain oedema are enrolled and assigned randomly to one of the two treatment study groups, labelled as M group' and HS group'. Patients in the M and HS groups receive intravenous infusion of 125mL of either 20% mannitol or 3.1% sodium chloride solution, respectively. Data will be collected immediately before the infusion of study agents, 15, 30, 60, 120, 240 and 360min after the start of infusion of experimental agents, which includes serum osmolality, concentration of serum sodium, potassium, urea and glucose. Serum osmolality will be measured by means of freezing point depression. Estimated serum osmolality will also be calculated by using four formulas published previously. Osmole gap is calculated as the difference between the measured and the estimated values. The primary endpoint is the correlation of measured and estimated serum osmolality during hyperosmolar agent infusion. Ethics and dissemination The study was approved by the International Review Board (IRB) of Beijing Tiantan Hospital, Capital Medical University. Study findings will be disseminated through peer-reviewed publications and conference presentations. Trial registration number ClinicalTrials.gov identifier: NCT02037815.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2013]版:
大类 | 4 区 医学
小类 | 4 区 医学:内科
最新[2023]版:
大类 | 3 区 医学
小类 | 3 区 医学:内科
JCR分区:
出版当年[2012]版:
Q2 MEDICINE, GENERAL & INTERNAL
最新[2023]版:
Q1 MEDICINE, GENERAL & INTERNAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2012版] 出版当年五年平均 出版前一年[2011版] 出版后一年[2013版]

第一作者:
第一作者机构: [1]Capital Med Univ, Beijing Tiantan Hosp, Dept Crit Care Med, Beijing, Peoples R China
通讯作者:
通讯机构: [1]Capital Med Univ, Beijing Tiantan Hosp, Dept Crit Care Med, Beijing, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院