当前位置: 首页 > 详情页

Clinical values of intraoperative indocyanine green fluorescence video angiography with Flow 800 software in cerebrovascular surgery

文献详情

资源类型:

收录情况: ◇ SCIE ◇ 统计源期刊 ◇ CSCD-C ◇ 中华系列

机构: [1]Capital Med Univ, Beijing Tiantan Hosp, Dept Neurosurg, Beijing 100050, Peoples R China; [2]Meitan Gen Hosp, Dept Neurosurg, Beijing 100028, Peoples R China
出处:
ISSN:

关键词: indocyanine green arteriovenous malformations moyamoya disease hemodynamic

摘要:
Background Microscope-integrated near-infrared indocyanine green video angiography (ICG-VA) has been used in neurosurgery for a decade.This study aimed to assess the value of intraoperative indocyanine green (ICG) video angiography with Flow 800 software in cerebrovascular surgery and to discover its hemodynamic features and changes of cerebrovascular diseases during surgery.Methods A total of 87 patients who received ICG-VA during various surgical procedures were enrolled in this study.Among them,45 cases were cerebral aneurysms,25 were cerebral arteriovenous malformations (AVMs),and 17 were moyamoya disease (MMD).A surgical microscope integrating an infrared fluorescence module was used to confirm the residual aneurysms and blocking of perforating arteries in aneurysms.Feeder arteries,draining veins,and normal cortical vessels were identified by the time delay color mode of Flow 800 software.Hemodynamic parameters were recorded.All data were analyzed by SPSS version 18.0 (SPSS Inc.,USA).T-test was used to analyze the hemodynamic features of AVMs and MMDs,the influence on peripheral cortex after resection in AVMs,and superficial temporal artery to middle cerebral artery (STA-MCA) bypass in MMDs.Results The visual delay map obtained by Flow 800 software had more advantages than the traditional playback mode in identifying the feeder arteries,draining veins,and their relations to normal cortex vessels.The maximum fluorescence intensity (MFI) and the slope of ICG fluorescence curve of feeder arteries and draining veins were higher than normal peripheral vessels (MFI:584.24±85.86 vs.382.94±91.50,slope:144.95±38.08 vs.69.20±13.08,P <0.05).The artefiovenous transit time in AVM was significantly shorter than in normal cortical vessels ((0.60±0.27) vs.(2.08±1.42) seconds,P <0.05).After resection of AVM,the slope of artery in the cortex increased,which reflected the increased cerebral flow.In patients with MMD,after STA-MCA bypass,cortex perfusion of corresponding branches region increased and local cycle time became shorter.Conclusion Intraoperative ICG video angiography combined with hemodynamic parameter analysis obtained by Flow 800 software appears to be useful for intraoperative monitoring of regional cerebral blood flow in cerebrovascular disease.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2012]版:
大类 | 4 区 医学
小类 | 4 区 医学:内科
最新[2023]版:
大类 | 3 区 医学
小类 | 3 区 医学:内科
JCR分区:
出版当年[2011]版:
Q3 MEDICINE, GENERAL & INTERNAL
最新[2023]版:
Q1 MEDICINE, GENERAL & INTERNAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2011版] 出版当年五年平均 出版前一年[2010版] 出版后一年[2012版]

第一作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院