机构:[a]Division of Advanced Manufacturing, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, Guangdong, China[b]Cardiac Surgery Center, Beijing Anzhen Hospital, Capital Medical University, Beijing 100029, China临床科室心脏外科中心首都医科大学附属安贞医院
BACKGROUND: A novel intra-ventricular assist device (iVAD) was established as a new pulsatile assist device to address various disadvantages, such as bulky configuration and reduced arterial pulsatility, observed in conventional ventricular assist devices. OBJECTIVE: Analyzed the native left ventricular stroke volume (SV) after iVAD support in vitro. METHODS: The SV of iVAD was examined in a home-designed mock circulatory system (MCS) at different heart rates and drive pressures and the SV of a failure ventricle was examined with iVAD at 75, 90, 120 bpm and 120-180 mmHg drive pressure after iVAD support. Data pertaining to native left ventricular SV before and after iVAD support were compared. RESULTS: The native ventricular SV was improved by iVAD when its drive pressure (DP) was slightly greater than that of the mock system. Conversely, the native ventricular SV was decreased when DP was much greater than that (150 mmHg) of MCS. A high DP had a significant effect on SV. CONCLUSIONS: The proposed device improved the dysfunctional native left ventricular SV when DP of iVAD was slightly greater than that of MCS. However, iVAD reduced the SV when the drive pressure was greater than that of MCS.
语种:
外文
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2017]版:
大类|4 区医学
小类|4 区工程:生物医学4 区卫生保健与服务
最新[2023]版:
大类|4 区医学
小类|4 区工程:生物医学4 区卫生保健与服务
JCR分区:
出版当年[2016]版:
Q4HEALTH CARE SCIENCES & SERVICESQ4ENGINEERING, BIOMEDICAL
最新[2023]版:
Q3HEALTH CARE SCIENCES & SERVICESQ4ENGINEERING, BIOMEDICAL
第一作者机构:[a]Division of Advanced Manufacturing, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, Guangdong, China
通讯作者:
通讯机构:[a]Division of Advanced Manufacturing, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, Guangdong, China[*1]A-216, Tsinghua Campus, The University Town, Shenzhen 518055, Guangdong, China.[*2]A-216, Tsinghua Campus, The University Town, Shenzhen 518055, Guangdong, China
推荐引用方式(GB/T 7714):
Shidong Zhu,Lin Luo,Bibo Yang,et al.Effects of an intra-ventricular assist device on the stroke volume of failing ventricle: Analysis of a mock circulatory system[J].TECHNOLOGY AND HEALTH CARE.2018,26(S1):S471-S479.doi:10.3233/THC-174752.
APA:
Shidong Zhu,Lin Luo,Bibo Yang,Kai Ni,Qian Zhou...&Xiaohao Wang.(2018).Effects of an intra-ventricular assist device on the stroke volume of failing ventricle: Analysis of a mock circulatory system.TECHNOLOGY AND HEALTH CARE,26,(S1)
MLA:
Shidong Zhu,et al."Effects of an intra-ventricular assist device on the stroke volume of failing ventricle: Analysis of a mock circulatory system".TECHNOLOGY AND HEALTH CARE 26..S1(2018):S471-S479