当前位置: 首页 > 详情页

Catheter Ablation for Atrial Fibrillation in Patients WithWatchman Left Atrial Appendage Occlusion Device: Results from a Multicenter Registry

文献详情

资源类型:

收录情况: ◇ SCIE

机构: [1]Univ Missouri Hosp & Clin, Div Cardiovasc Dis, Columbia, MO USA; [2]Univ Kansas Hosp & Med Ctr, Div Cardiovasc Dis, Cardiovasc Res Inst, 3901 Rainbow Blvd, Kansas City, KS 66160 USA; [3]Montefiore Med Ctr, 111 E 210th St, Bronx, NY 10467 USA; [4]Texas Cardiac Arrhythmia Ctr, Austin, TX USA; [5]Capital Med Univ, Beijing Anzhen Hosp, Beijing, Peoples R China; [6]Arizona Heart Rhythm Inst, Phoenix, AZ USA; [7]Texas Heart Inst, Houston, TX 77025 USA
出处:
ISSN:

关键词: atrial fibrillation catheter ablation left atrial appendage exclusion left atrial appendage triggers pulmonary vein isolation Watchman device

摘要:
Background: There have been an increasing number of atrial fibrillation (AF) patients with Watchman left atrial appendage occlusion (LAAO) device, requiring catheter ablation (CA) for maintenance of normal sinus rhythm. In this study, we describe our experience with the feasibility and safety of CA in patients with a preexisting Watchman LAAO device. Methods: This was a retrospective multicenter AF registry of 60 patients with Watchman LAAO device who underwent CA for AF. Baseline clinical and procedural characteristics of the included subjects were retrieved from review of medical records and were analyzed. Results: The mean age was 72.7 +/- 4.9 years and the mean CHADS2 score was 2.3 +/- 0.6. All patients had successful pulmonary vein isolation (PVI). The left atrial appendage (LAA) was electrically active in 34 (56%) while reentrant tachycardia and AF triggers were seen in 17 (28%) patients. Electrical isolation was attempted in these 17 patients with only 10 achieving complete LAA isolation. Repeat imaging showed new peri-device leaks in 30% (12/ 40) patients, while new significant peri-device leaks (>= 5 mm) were noted in 10% (10/ 40) of patients after RFA, respectively, requiring continuation of oral anticoagulation. There were a higher proportion of patients with severe peri-device leaks ( >= 5 mm) after LAA isolation. However, > 50% of those leaks sealed off on follow-up transesophageal echocardiogram. Conclusion: AF ablation is a feasible and safe in patients with preexisting Watchman LAAO device. Electrical isolation of the LAA could be difficult and when attempted can result in increased risk of shortterm peri-device leak and recurrence of AT/AF in almost all patients.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2016]版:
大类 | 3 区 医学
小类 | 3 区 心脏和心血管系统
最新[2023]版:
大类 | 3 区 医学
小类 | 3 区 心脏和心血管系统
JCR分区:
出版当年[2015]版:
Q2 CARDIAC & CARDIOVASCULAR SYSTEMS
最新[2023]版:
Q2 CARDIAC & CARDIOVASCULAR SYSTEMS

影响因子: 最新[2023版] 最新五年平均 出版当年[2015版] 出版当年五年平均 出版前一年[2014版] 出版后一年[2016版]

第一作者:
第一作者机构: [1]Univ Missouri Hosp & Clin, Div Cardiovasc Dis, Columbia, MO USA;
通讯作者:
通讯机构: [2]Univ Kansas Hosp & Med Ctr, Div Cardiovasc Dis, Cardiovasc Res Inst, 3901 Rainbow Blvd, Kansas City, KS 66160 USA;
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16399 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院