当前位置: 首页 > 详情页

Transvenous versus open chest lead placement for resynchronization therapy in patients with heart failure: comparison of ventricular electromechanical synchronicity

文献详情

资源类型:

收录情况: ◇ SCIE ◇ CSCD-C

机构: [1]Capital Med Univ, Beijing Anzhen Hosp, Cardiac Surg Dept, 2 Anzhen St, Beijing 100029, Peoples R China; [2]Capital Med Univ, Beijing Anzhen Hosp, Echocardiog Dept, Beijing, Peoples R China; [3]Capital Med Univ, Beijing Anzhen Hosp, Cardiol Dept, Beijing, Peoples R China
出处:
ISSN:

关键词: Heart failure Resynchronization Tissue Doppler imaging

摘要:
Background Transvenous lead placement is the standard approach for left ventricular (LV) pacing in cardiac resynchronization therapy (CRT), while the open chest access epicardial lead placement is currently the most frequently used second choice. Our study aimed to compare the ventricular electromechanical synchronicity in patients with heart failure after CRT with these two different LV pacing techniques. Methods We enrolled 33 consecutive patients with refractory heart failure secondly to dilated cardiomyopathy who were eligible for CRT in this study. Nineteen patients received transvenous (TV group) while 14 received open chest (OP group) LV lead pacing. Intraand inter-ventricular electromechanical synchronicity was assessed by tissue Doppler imaging (TDI) before and one year after CRT procedure. Results Before CRT procedure, the mean QRS-duration, maximum time difference to systolic peak velocity among 12 left ventricle segments (LV Ts-12), standard deviation of time difference to systolic peak velocity of 12 left ventricle segments (LV Ts-SD), and inter-ventricular mechanical delay (IVMD) in OP and TV group were 166 +/- 17 ms and 170 +/- 21 ms, 391 +/- 42 ms and 397 +/- 36 ms, 144 +/- 30 ms and 148 +/- 22 ms, 58 +/- 25 ms and 60 +/- 36 ms, respectively (all P > 0.05). At one year after the CRT, the mean QRS-duration, LV Ts-12, LV Ts-SD, and IVMD in TV and OP group were 128 +/- 14 ms and 141 +/- 22 ms (P = 0.031), 136 +/- 37 ms and 294 +/- 119 ms (P = 0.023), 50 +/- 22 ms and 96 +/- 34 ms (P = 0.015), 27 +/- 11 ms and 27 +/- 26 ms (P = 0.86), respectively. The LV lead implantation procedure time was 53.4 +/- 16.3 min for OP group and 136 +/- 35.1 min for TV group (P = 0.016). The mean LV pacing threshold increased significantly from 1.7 +/- 0.6 V/0.5 ms to 2.3 +/- 1.6 V/0.5 ms (P < 0.05) in TV group while it remained stable in the OP group. Conclusions Compared to conventional endovascular approach, open chest access of LV pacing for CRT leads to better improvement of the intraventricular synchronization.

语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2016]版:
大类 | 4 区 医学
小类 | 4 区 心脏和心血管系统 4 区 老年医学
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 心脏和心血管系统 4 区 老年医学
JCR分区:
出版当年[2015]版:
Q3 CARDIAC & CARDIOVASCULAR SYSTEMS Q4 GERIATRICS & GERONTOLOGY
最新[2023]版:
Q3 CARDIAC & CARDIOVASCULAR SYSTEMS Q3 GERIATRICS & GERONTOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2015版] 出版当年五年平均 出版前一年[2014版] 出版后一年[2016版]

第一作者:
第一作者机构: [1]Capital Med Univ, Beijing Anzhen Hosp, Cardiac Surg Dept, 2 Anzhen St, Beijing 100029, Peoples R China;
通讯作者:
通讯机构: [1]Capital Med Univ, Beijing Anzhen Hosp, Cardiac Surg Dept, 2 Anzhen St, Beijing 100029, Peoples R China;
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院