Hemodynamics of the string phenomenon in the internal thoracic artery grafted to the left anterior descending artery with moderate stenosis

文献详情

资源类型:

收录情况: ◇ SCIE ◇ EI

机构: [1]Beijing Univ Technol, Coll Life Sci & Bioengn, 100 Pingleyuan, Beijing 100124, Peoples R China; [2]Capital Med Univ, Beijing An Zhen Hosp, 2 Anzhen Rd Chaoyang Dist, Beijing 100029, Peoples R China; [3]Peking Univ, Peoples Hosp, 11 Xizhimen South St Xicheng Dist, Beijing 100044, Peoples R China
出处:
ISSN:

关键词: Internal thoracic artery graft 0D/3D coupling simulation Hemodynamics Coronary artery bypass grafting (CABG) Computational fluid dynamics (CFD)

摘要:
Purpose: The internal thoracic artery is the choice of graft for coronary artery bypass grafting due to the excellent long-term patency. However internal thoracic artery graft failures still occur due to diffuse narrowing, known as the string phenomenon. Studies suggest that the string phenomenon is caused by competitive flow when the coronary stenosis is not serious, but the hemodynamics of the string phenomenon are still unclear. The purpose of this study is to clarify the hemodynamic characteristics of the string phenomenon. Materials: A patient-specific 3-dimensional model of the aortic arch and coronary arteries was reconstructed. A moderate stenosis was applied to the left anterior descending artery. The internal thoracic artery was used to bypass the stenosis. Two further 3D models were built to study the hemodynamics of the string phenomenon. Methods: A numerical study was performed by coupling the 3D artery model with 0-dimensional lumped parameter model of the cardiovascular system. Results: The graft flow, native coronary flow, wall shear stress and oscillatory shear index were calculated and illustrated. Inverse flow and high oscillatory shear index appeared on the internal thoracic artery graft when the stenosis was moderate. Conclusion: High oscillatory shear index might be the major hemodynamic characteristic of the string phenomenon in internal thoracic artery graft. The inverse graft flow and,the difference in graft flow caused by clamping the stenosis can be used to evaluate the probability of observing the string phenomenon. (C) 2015 Elsevier Ltd. All rights reserved.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2015]版:
大类 | 3 区 生物
小类 | 3 区 工程:生物医学 4 区 生物物理
最新[2023]版:
大类 | 3 区 医学
小类 | 2 区 生物物理 3 区 工程:生物医学
JCR分区:
出版当年[2014]版:
Q2 BIOPHYSICS Q2 ENGINEERING, BIOMEDICAL
最新[2023]版:
Q3 ENGINEERING, BIOMEDICAL Q3 BIOPHYSICS

影响因子: 最新[2023版] 最新五年平均 出版当年[2014版] 出版当年五年平均 出版前一年[2013版] 出版后一年[2015版]

第一作者:
第一作者机构: [1]Beijing Univ Technol, Coll Life Sci & Bioengn, 100 Pingleyuan, Beijing 100124, Peoples R China;
通讯作者:
通讯机构: [1]Beijing Univ Technol, Coll Life Sci & Bioengn, 100 Pingleyuan, Beijing 100124, Peoples R China;
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院