Coronary Computed Tomographic Angiography in Coronary Artery Bypass Grafts: Comparison Between Low-Concentration Iodixanol 270 and Iohexol 350

文献详情

资源类型:

收录情况: ◇ SCIE

机构: [1]Capital Med Univ, Beijing Anzhen Hosp, Dept Radiol, Beijing 100029, Peoples R China; [2]Curtin Univ, Dept Imaging & Appl Phys, Discipline Med Imaging, Perth, WA 6845, Australia; [3]Capital Med Univ, Beijing Anzhen Hosp, Dept Radiol, 2 Anzhen Rd, Beijing 100029, Peoples R China
出处:
ISSN:

关键词: contrast media coronary CT angiography bypass grafts cardiac imaging low-concentration contrast media

摘要:
Objective: The aim of this study was to evaluate the feasibility of low-concentration iso-osmolar Iodixanol 270 compared with Iohexol 350 in patients with coronary artery bypass grafts (CABGs) undergoing coronary computed tomographic angiography (CCTA). Methods: A total of 80 consecutive patients undergoing CABG follow-up with the use of CCTA were prospectively enrolled, with 40 patients assigned to Iodixanol 270 and 40 patients assigned to Iohexol 350. In both groups, the contrast medium was injected at an injection rate of 4.5 mL/s in the patients with a body mass index of greater than 24 kg/m(2) and 3.5 mL/s in the patients with a body mass index of 24 kg/m(2) or lower. The contrast volume was determined by the flow rate and scan time. Image quality score and visualization of bypass grafts were evaluated. Subjective assessment of image quality for each coronary artery segment was determined using a 4-point grading scale by 2 reviewers, whereas objective evaluation of image quality was conducted by measuring the mean CT attenuation values (hounsfield unit [HU]) in terms of SD, contrast-noise ratio, and signal-noise ratio in the ascending aorta. Results: The mean (SD) contrast volume for the Iodixanol 270 and Iohexol 350 groups was 66.28 (12.00) and 64.98 (8.12) mL, respectively, with no significant difference (P = 0.57). The mean (SD) CT attenuation value in the Iodixanol 270 group was 414.72 (101.47), which was lower than in the Iohexol 350 group, which was 478.85 (108.73) (P = 0.01). The subjective image quality for the Iodixanol 270 group was superior to that for the Iohexol 350 group in the arterial graft vessels (P = 0.027), whereas there was no significant difference between the 2 groups in the venous graft vessels (P = 0.377). There was no significant difference in terms of SD of the ascending aorta, signal-noise ratio, and contrast-noise ratio between the 2 groups. Conclusions: Low-concentration iso-osmolar Iodixanol 270 provides image quality comparable with that of Iohexol 350, allowing diagnostic CCTA follow-up of patients with CABGs.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2014]版:
大类 | 4 区 医学
小类 | 4 区 核医学
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 核医学
JCR分区:
出版当年[2013]版:
Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2013版] 出版当年五年平均 出版前一年[2012版] 出版后一年[2014版]

第一作者:
第一作者机构: [1]Capital Med Univ, Beijing Anzhen Hosp, Dept Radiol, Beijing 100029, Peoples R China;
通讯作者:
通讯机构: [1]Capital Med Univ, Beijing Anzhen Hosp, Dept Radiol, Beijing 100029, Peoples R China; [3]Capital Med Univ, Beijing Anzhen Hosp, Dept Radiol, 2 Anzhen Rd, Beijing 100029, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:17005 今日访问量:0 总访问量:905 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院