Aims Transient ST-T elevation (STE) is a rare complication that occurs during transseptal catheterization. This study aims to delineate the incidence and characteristics of transient STE during transseptal catheterization for atrial fibrillation (AF) ablation. Methods and results Consecutive patientswhounderwent fluoroscopy-guided transseptal catheterization for circumferential pulmonary vein radiofrequency ablation in Beijing AnZhen Hospital from January 2006 to January 2013 were enrolled in this study. Out of 2965 patients with a total of 3452 transseptal catheterization procedures, 13 patients (0.38%, mean age 57 +/- 8, 6 female, 12 paroxysmal AF, mean left atrial diameter 35.4 +/- 3.8 mm) had STE. ST-T elevation occurred after transseptal puncture in 10 patients and after pulmonary vein venography in three patients. Systolic blood pressure (129 +/- 10 vs. 104 +/- 20 mmHg, P < 0.001), diastolic blood pressure (78 +/- 6 vs. 64 +/- 11 mmHg, P < 0.001), and heart rate (83 +/- 19 bpm vs. 64 +/- 23 b.p.m., P = 0.022) significantly decreased when STE occurred. Eleven patients complained of chest pain, one patient complained of dizziness, and one patient had no symptoms. Patients recovered in about 4.6 min (2-10 min) with dopamine or fast saline drip. Catheter ablation of AF was completed in all the 13 patients without sequelae or other complications. Four of the 13 patients (30.8%) had recurrence of AF after a mean follow-up of 21.7 months. Conclusion ST-T elevation is a rare complication associated with transseptal catheterization without sequelae. Catheter ablation of AF could be safely completed in these patients.
基金:
National Science Foundation Council of ChinaNational Natural Science Foundation of China [30900628, 81241005]; Beijing Natural Science FoundationBeijing Natural Science Foundation [7102048]; Beijing Nova ProgramBeijing Municipal Science & Technology Commission [2009B32]; Training Program for Excellent Talent of Beijing [2010D003034000025]; High Levels Talent in Health in Beijing [2013-03-007]; National Science and Technology Support Program [2012BAI14B04]
第一作者机构:[1]Capital Med Univ, Beijing An Zhen Hosp, Beijing Inst Heart Lung & Blood Vessel Dis, Dept Cardiol, Beijing 100029, Peoples R China;
通讯作者:
通讯机构:[1]Capital Med Univ, Beijing An Zhen Hosp, Beijing Inst Heart Lung & Blood Vessel Dis, Dept Cardiol, Beijing 100029, Peoples R China;
推荐引用方式(GB/T 7714):
Tang Ri-Bo,Dong Jian-Zeng,Long De-Yong,et al.Incidence and clinical characteristics of transient ST-T elevation during transseptal catheterization for atrial fibrillation ablation[J].EUROPACE.2015,17(4):579-583.doi:10.1093/europace/euu278.
APA:
Tang, Ri-Bo,Dong, Jian-Zeng,Long, De-Yong,Yu, Rong-Hui,Liu, Xing-Peng...&Ma, Chang-Sheng.(2015).Incidence and clinical characteristics of transient ST-T elevation during transseptal catheterization for atrial fibrillation ablation.EUROPACE,17,(4)
MLA:
Tang, Ri-Bo,et al."Incidence and clinical characteristics of transient ST-T elevation during transseptal catheterization for atrial fibrillation ablation".EUROPACE 17..4(2015):579-583