当前位置: 首页 > 详情页

Performance of Automated Software in the Assessment of Segmental Left Ventricular Function in Cardiac CT: Comparison with Cardiac Magnetic Resonance

文献详情

资源类型:

收录情况: ◇ SCIE

机构: [1]Med Univ S Carolina, Dept Radiol & Radiol Sci, Charleston, SC 29425 USA; [2]Capital Med Univ, Beijing Anzhen Hosp, Dept Radiol, Beijing, Peoples R China; [3]Ludwig Maximilians Univ Hosp, Inst Clin Radiol, Munich, Germany; [4]Med Univ S Carolina, Dept Med, Div Cardiol, Charleston, SC 29425 USA; [5]Siemens Med Solut USA, Malvern, PA USA; [6]Univ Roma La Sapienza, Dept Radiol Sci, Latina, Italy; [7]Univ Roma La Sapienza, Dept Oncol, Latina, Italy; [8]Univ Roma La Sapienza, Dept Pathol, Latina, Italy; [9]Med Univ S Carolina, Dept Radiol & Radiol Sci, 25 Courtenay Dr,MSC 226, Charleston, SC 29425 USA
出处:
ISSN:

关键词: Coronary artery disease Cardiac function Post processing Cardiac computed tomography Cardiac magnetic resonance

摘要:
To evaluate the accuracy, reliability and time saving potential of a novel cardiac CT (CCT)-based, automated software for the assessment of segmental left ventricular function compared to visual and manual quantitative assessment of CCT and cardiac magnetic resonance (CMR). Forty-seven patients with suspected or known coronary artery disease (CAD) were enrolled in the study. Wall thickening was calculated. Segmental LV wall motion was automatically calculated and shown as a colour-coded polar map. Processing time for each method was recorded. Mean wall thickness in both systolic and diastolic phases on polar map, CCT, and CMR was 9.2 +/- 0.1 mm and 14.9 +/- 0.2 mm, 8.9 +/- 0.1 mm and 14.5 +/- 0.1 mm, 8.3 +/- 0.1 mm and 13.6 +/- 0.1 mm, respectively. Mean wall thickening was 68.4 +/- 1.5 %, 64.8 +/- 1.4 % and 67.1 +/- 1.4 %, respectively. Agreement for the assessment of LV wall motion between CCT, CMR and polar maps was good. Bland-Altman plots and ICC indicated good agreement between CCT, CMR and automated polar maps of the diastolic and systolic segmental wall thickness and thickening. The processing time using polar map was significantly decreased compared with CCT and CMR. Automated evaluation of segmental LV function with polar maps provides similar measurements to manual CCT and CMR evaluation, albeit with substantially reduced analysis time. aEuro cent Cardiac computed tomography (CCT) can accurately assess segmental left ventricular wall function. aEuro cent A novel automated software permits accurate and fast evaluation of wall function. aEuro cent The software may improve the clinical implementation of segmental functional analysis.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2014]版:
大类 | 2 区 医学
小类 | 2 区 核医学
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 核医学
JCR分区:
出版当年[2013]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2024]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2024版] 最新五年平均 出版当年[2013版] 出版当年五年平均 出版前一年[2012版] 出版后一年[2014版]

第一作者:
第一作者机构: [1]Med Univ S Carolina, Dept Radiol & Radiol Sci, Charleston, SC 29425 USA; [2]Capital Med Univ, Beijing Anzhen Hosp, Dept Radiol, Beijing, Peoples R China;
通讯作者:
通讯机构: [1]Med Univ S Carolina, Dept Radiol & Radiol Sci, Charleston, SC 29425 USA; [4]Med Univ S Carolina, Dept Med, Div Cardiol, Charleston, SC 29425 USA; [9]Med Univ S Carolina, Dept Radiol & Radiol Sci, 25 Courtenay Dr,MSC 226, Charleston, SC 29425 USA
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:17607 今日访问量:0 总访问量:938 更新日期:2025-07-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院