CT coronary angiography: Image quality with sinogram-affirmed iterative reconstruction compared with filtered back-projection

文献详情

资源类型:

收录情况: ◇ SCIE

机构: [1]Capital Med Univ, Beijing Anzhen Hosp, Dept Radiol, Beijing 100029, Peoples R China; [2]Med Univ S Carolina, Dept Radiol & Radiol Sci, Charleston, SC 29425 USA; [3]Siemens Healthcare China, Beijing, Peoples R China
出处:
ISSN:

摘要:
AIM: To investigate image quality and potential for radiation dose reduction using sinogram-affirmed iterative reconstruction (SAFIRE) at computed tomography (CT) coronary angiography (CTCA) compared with filtered back-projection (FBP) reconstruction. MATERIALS AND METHODS: A water phantom and 49 consecutive patients were scanned using a retrospectively electrocardiography (ECG)-gated CTCA protocol on a dual-source CT system. Image reconstructions were performed with both conventional FBP and SAFIRE. The SAFIRE series were reconstructed image data from only one tube, simulating a 50% radiation dose reduction. Two blinded observers independently assessed the image quality of each coronary segment using a four-point scale and measured image noise (the standard deviation of Hounsfield values, SD), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). Radiation dose estimates were calculated. RESULTS: In the water phantom, image noise decreased at the same ratio as the tube current increased for both reconstruction algorithms. Despite an estimated radiation dose reduction from 7.9 +/- 2.8 to 4 +/- 1.4 mSv, there was no significant difference in the SD and SNR within the aortic root and left ventricular chamber between the two reconstruction methods. There was also no significant difference in the image quality between the FBP and SAFIRE series. CONCLUSION: Compared with traditional FBP, there is potential for substantial radiation dose reduction at CTCA with use of SAFIRE, while maintaining similar diagnostic image quality. (C) 2012 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2012]版:
大类 | 4 区 医学
小类 | 4 区 核医学
最新[2023]版:
大类 | 3 区 医学
小类 | 3 区 核医学
JCR分区:
出版当年[2011]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2011版] 出版当年五年平均 出版前一年[2010版] 出版后一年[2012版]

第一作者:
第一作者机构: [1]Capital Med Univ, Beijing Anzhen Hosp, Dept Radiol, Beijing 100029, Peoples R China;
通讯作者:
通讯机构: [1]Capital Med Univ, Beijing Anzhen Hosp, Dept Radiol, Beijing 100029, Peoples R China;
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院