Application of spatio-temporal image correlation technology in the diagnosis of fetal cardiac abnormalities

文献详情

资源类型:

收录情况: ◇ SCIE

机构: [1]Capital Med Univ, Beijing Anzhen Hosp, Dept Ultrasound, Beijing 100029, Peoples R China; [2]Capital Med Univ, Beijing Anzhen Hosp, Dept Ultrasound, 2th Anzhen Rd, Beijing 100029, Peoples R China
出处:
ISSN:

关键词: fetal cardiac abnormality spatio-temporal image correlation technology fetal echocardiography pathology

摘要:
Congenital heart disease is the birth defect with the highest incidence in China. Its timely and accurate prenatal diagnosis is critical for appropriate perinatal and postnatal management and salvage treatment. With improvements in the diagnostic capabilities of ultrasound and clinical manipulation techniques, prenatal diagnosis is conducted increasingly early and with greater accuracy. However, the representations of tiny blood vessels and the determination of abnormal spatial structures in the fetal period continue to cause difficulties in prenatal diagnosis. In theory, spatio-temporal image correlation (STIC) technology is able to compensate for the defects of previous traditional two-dimensional (2D) ultrasound and improve the diagnostic accuracy. The aim of the present study was to investigate the clinical application value of STIC technology combined with traditional 2D ultrasound in the diagnosis of fetal cardiac abnormalities. A total of 1,286 fetuses were subjected to sequential echocardiographic examination, during which STIC technology was used to collect heart volume data and carry out image post-processing and off-line analysis. In addition, the prenatal and postnatal echocardiography results were compared with the pathology results following the induced labor of fetuses with cardiac abnormalities. The sensitivity, specificity, misdiagnosis rate and rate of missed diagnosis for the STIC technology in the diagnosis of prenatal fetal cardiac abnormalities were 97.4, 99.6, 0.4 and 2.6%, respectively. The total coincidence rate was 99.2% and the positive and negative predictive values were 97.9 and 99.4%, respectively; the statistics for the consistency check of the STIC technology in the diagnosis of fetal cardiac abnormalities are kappa=0.991, P=0.000. STIC technology combined with fetal echocardiography may be used for the definite diagnosis of fetal heart malformations, with high sensitivity and specificity.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2012]版:
大类 | 4 区 医学
小类 | 4 区 医学:研究与实验
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 医学:研究与实验
JCR分区:
出版当年[2011]版:
Q4 MEDICINE, RESEARCH & EXPERIMENTAL
最新[2023]版:
Q3 MEDICINE, RESEARCH & EXPERIMENTAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2011版] 出版当年五年平均 出版前一年[2010版] 出版后一年[2012版]

第一作者:
第一作者机构: [1]Capital Med Univ, Beijing Anzhen Hosp, Dept Ultrasound, Beijing 100029, Peoples R China;
通讯作者:
通讯机构: [1]Capital Med Univ, Beijing Anzhen Hosp, Dept Ultrasound, Beijing 100029, Peoples R China; [2]Capital Med Univ, Beijing Anzhen Hosp, Dept Ultrasound, 2th Anzhen Rd, Beijing 100029, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16461 今日访问量:0 总访问量:871 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院