当前位置: 首页 > 详情页

Can EuroSCORE II Predict the Mortality and Length of Intensive Care Unit Stay after Total Aortic Arch Replacement with Stented Elephant Trunk Implantation for DeBakey Type I Aortic Dissection?

文献详情

资源类型:

收录情况: ◇ SCIE

机构: [1]Capital Med Univ, Beijing Anzhen Hosp, Dept Cardiovasc Surg, Beijing Aort Dis Ctr, Beijing 100029, Peoples R China; [2]Capital Med Univ, Beijing Anzhen Hosp, Dept Cardiovasc Surg, Beijing Aort Dis Ctr, 2 Anzhen Rd, Beijing 100029, Peoples R China
出处:
ISSN:

关键词: EuroSCORE II mortality aortic dissection intensive care unit

摘要:
Background EuroSCORE is a widely used objective risk scoring model. Objective The aim of this study was to evaluate the validation of EuroSCORE II for predicting in-hospital mortality and length of intensive care unit (ICU) stay after total aortic arch replacement with stented elephant trunk implantation for DeBakey Type I aortic dissection. Patients and Methods Between February 2009 and February 2012, data from 384 consecutive patients, who underwent aortic surgery using total aortic arch replacement with stented elephant trunk implantation, were collected retrospectively. EuroSCORE II was applied to predict mortality and length of ICU stay. The C-statistic was used to test discrimination of the model. Calibration was assessed with the Hosmer-Lemeshow goodness-of-fit statistic. Results The in-hospital mortality was 8.07%. The mean length of ICU stay was 3.06 days. A total of 75 patients remained at ICU for 5 days or more and 42 patients for 7 days or more. EuroSCORE II did not show good discriminatory ability in predicting mortality and length of ICU stay. The C-statistic of predicting mortality, ICU stay for 5 days or more, and ICU stay for 7 days or more were 0.49, 0.56, and 0.52, respectively. The calibration was poor for predicting mortality (p < 0.001), ICU stay for 5 days or more (p < 0.001), and ICU stay for 7 days or more (p < 0.001). Conclusion Although EuroSCORE II is the newest risk model for cardiac surgery, it is not accurate when it is applied for thoracic aortic surgery. A new risk evaluating system specially designed for aortic surgery should be developed in the future.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2012]版:
大类 | 4 区 医学
小类 | 4 区 心脏和心血管系统 4 区 呼吸系统 4 区 外科
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 心脏和心血管系统 4 区 呼吸系统 4 区 外科
JCR分区:
出版当年[2011]版:
Q3 SURGERY Q4 RESPIRATORY SYSTEM Q4 CARDIAC & CARDIOVASCULAR SYSTEMS
最新[2023]版:
Q3 CARDIAC & CARDIOVASCULAR SYSTEMS Q3 SURGERY Q4 RESPIRATORY SYSTEM

影响因子: 最新[2023版] 最新五年平均 出版当年[2011版] 出版当年五年平均 出版前一年[2010版] 出版后一年[2012版]

第一作者:
第一作者机构: [1]Capital Med Univ, Beijing Anzhen Hosp, Dept Cardiovasc Surg, Beijing Aort Dis Ctr, Beijing 100029, Peoples R China;
通讯作者:
通讯机构: [1]Capital Med Univ, Beijing Anzhen Hosp, Dept Cardiovasc Surg, Beijing Aort Dis Ctr, Beijing 100029, Peoples R China; [2]Capital Med Univ, Beijing Anzhen Hosp, Dept Cardiovasc Surg, Beijing Aort Dis Ctr, 2 Anzhen Rd, Beijing 100029, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院