当前位置: 首页 > 详情页

128-Slice Acceletated-Pitch Dual Energy CT Angiography of the Head and Neck: Comparison of Different Low Contrast Medium Volumes

文献详情

资源类型:

收录情况: ◇ SCIE

机构: [1]Chinese Acad Med Sci, Peking Union Med Coll Hosp, Dept Radiol, Beijing 100730, Peoples R China; [2]Nanjing Univ, Sch Clin, Coll Med, Jinling Hosp,Dept Med Imaging, Nanjing 210008, Jiangsu, Peoples R China; [3]Capital Med Univ, Beijing Inst Heart Lung & Blood Vessel Dis, Dept Radiol, Beijing, Peoples R China; [4]Capital Med Univ, Beijing Anzhen Hosp, Beijing, Peoples R China; [5]Med Univ S Carolina, Dept Radiol & Radiol Sci, Charleston, SC 29425 USA
出处:
ISSN:

摘要:
Background: Our study aims to evaluate the image quality and feasibility of 128-slice dual-energy CTA (DE-CTA) for supra-aortic arteries using reduced amounts of contrast medium (CM). Methods: A prospective study was performed in 54 patients receiving CTA of the head and neck with a 128-slice dual-source CT system. Patients were randomized into two groups with a volume of either 40 mL of CM (Group I) or 50 mL of CM (Group II). Arterial and venous enhancements were recorded for quantitative assessment. Qualitative assessments for images without bone removal (BR) were based on a) the visualization of the circle of Willis and b) streak artifacts due to residual CM in the subclavian or internal jugular veins ipsilateral to injection of CM. Qualitative assessment of dual-energy images using BR was based on the presence of bone remnants and vessel integrity. Quantitative data was compared using the Student t test. The chi(2) test was used for the qualitative measurements of streak artifacts in veins while the Mann-Whitney U test was used for the qualitative measurements of images with BR. Results: Arterial and venous attenuation was significantly higher in Group II (P=0.000). Image quality regarding the circle of Willis was excellent in both groups (3.90 +/- 0.30 for Group I and 4.00 +/- 0 for Group II). Imaging of the internal jugular veins was scored higher in Group I (1.87 +/- 0.72) compared with Group II (1.48 +/- 0.51) (P=0.021). Within Group I using BR, mean scores for bone remnants did not differ significantly (P>0.05) but mean scores of vessel integrity (P<0.05) did. Conclusions: Contrast-enhanced head and neck CTA is feasible using a scan protocol with low amounts of contrast medium (40 mL) on a 128-slice dual-energy CTA. The 40-mL protocol provides satisfactory image quality before and after dual-energy bone-removal post-processing.

语种:
被引次数:
WOS:
中科院(CAS)分区:
出版当年[2012]版:
大类 | 2 区 生物
小类 | 2 区 生物学
最新[2023]版:
大类 | 3 区 综合性期刊
小类 | 3 区 综合性期刊
JCR分区:
出版当年[2011]版:
Q1 BIOLOGY
最新[2023]版:
Q1 MULTIDISCIPLINARY SCIENCES

影响因子: 最新[2023版] 最新五年平均 出版当年[2011版] 出版当年五年平均 出版前一年[2010版] 出版后一年[2012版]

第一作者:
第一作者机构: [1]Chinese Acad Med Sci, Peking Union Med Coll Hosp, Dept Radiol, Beijing 100730, Peoples R China;
通讯作者:
通讯机构: [1]Chinese Acad Med Sci, Peking Union Med Coll Hosp, Dept Radiol, Beijing 100730, Peoples R China;
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院