[A comparison of ventilation/perfusion single photon emission CT and CT pulmonary angiography for diagnosis of pulmonary embolism].

| 认领 | 导出 |

文献详情

资源类型:

收录情况: ◇ 统计源期刊 ◇ 北大核心 ◇ CSCD-C ◇ 中华系列

机构: [1]Department of Nuclear Medicine, Beijing Anzhen Hospital, Capital Medical University, Beijing, 100029, China
出处:
ISSN:

摘要:
To assess the diagnostic accuracy of ventilation/perfusion (V/Q) single photon emission CT (SPECT) as compared to computed tomographic pulmonary angiography (CTPA) for pulmonary embolism (PE). In this prospective multicenter study, 111 patients in whom acute or sub-acute PE was clinically confirmed or suspected were enrolled. The patients underwent one-day method V/Q lung scan (including SPECT and planar imaging) within 3 days before and after completion of CTPA. The European Association of Nuclear Medicine (EANM) guidelines for ventilation/perfusion scintigraphy (2009) reference was used as the evaluation criteria of V/Q SPECT imaging. The refined modified prospective investigation of pulmonary embolism diagnosis (RM-PIOPED) criteria was used for evaluation of planar imaging. According to the direct and indirect signs of PE, the imaging of CTPA was evaluated. All patients were followed for at least 6 months. A diagnosis was finally made by consensus of respiratory physicians, radiologists and nuclear medicine physicians based on the clinical data, laboratory tests, imaging features and follow-up results. The difference among diagnostic methods was evaluated for significance using chi-square test. The receiver operator characteristic (ROC) curve was drawn according to the results of the 3 diagnostic tests. The area under ROC curve (AUC) was calculated and compared. P < 0.05 was considered statistically significant. Among the 111 patients, PE was confirmed in 80, and excluded in 31. The diagnostic sensitivity/specificity/accuracy of V/Q SPECT, planar imaging, and CTPA were 85.9%/93.5%/88.1%, 75.7%/92.9%/81.4%, and 85.5%/90.0%/86.8%, respectively. By ROC curve analysis, the AUC values of V/Q SPECT, planar imaging and CTPA were 0.898, 0.838, and 0.877, respectively; with 95% confidence intervals [CI] 0.831 to 0.966, 0.759 to 0.917, and 0.801 to 0.954, respectively. The area of the fitted smooth ROC curve was statistically significant (P < 0.05) as compared with the area under the reference line. The results indicate that SPECT V/Q imaging is superior to V/Q planar scan and CTPA in the diagnosis of PE.

语种:
第一作者:
第一作者机构: [1]Department of Nuclear Medicine, Beijing Anzhen Hospital, Capital Medical University, Beijing, 100029, China
推荐引用方式(GB/T 7714):

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院