当前位置: 首页 > 详情页

Procedural results and 30-day clinical events analysis following Edwards transcatheter aortic valve implantation in 48 consecutive patients: initial experience

文献详情

资源类型:

收录情况: ◇ SCIE ◇ 统计源期刊 ◇ CSCD-C ◇ 中华系列

机构: [1]Univ Hosp Caen, Dept Cardiol, F-14000 Caen, France; [2]Capital Med Univ, Beijing Anzhen Hosp, Dept Cardiol, Beijing 100029, Peoples R China; [3]Univ Hosp Caen, Dept Cardiac Surg, F-14000 Caen, France;
出处:
ISSN:

关键词: aortic stenosis transcatheter aortic valve implantation registry

摘要:
Background Transcatheter aortic valve implantation (TAVI) is a rapidly evolving strategy for therapy of aortic stenosis.We presented the procedural results and analyzed the death causes of 30-day mortality and clinical events in patients who underwent TAVI with Edwards prosthetic valves in University Hospital of Caen,France.Methods The patients with severe aortic stenosis but at high surgical risk or inoperable were considered as candidates for TAVI.Forty-eight patients undergoing TAVI from July 2010 to September 2011 were enrolled in this registry.The Edwards prosthetic valves were solely used in this clinical trial.Results Overall 48 patients underwent TAVI,28 of which accepted TAVI by trans-femoral (TF) approaches,20 by trans-apical approaches (TA).The aortic valve area (AVA) was (0.70±0.23) cm2,left ventricular ejection fraction (LVEF)was (57.4±17.6)%,Log EuroSCORE was (19.2±15.8)%,mean gradient was (47.0±16.6) mmHg.There were no significant differences between TF and TA groups in all these baseline parameters.Device success rate was 95.8%,and procedural success rate was 93.7% in total.Procedural mortality was 6.7% (3/48):two deaths in TA group (10%),and one death in TF group (3.6%).Forty-six Edwards valves were implanted:10 Edwards Sapien and 36 Edwards XT.Procedure-related complications included cardiac tamponade in 2 cases (4.2%),acute myocardial infarction (AMI) in 1 case (2.1%),permanent pacemaker implantation in 1 case (2.1%),life-threatening and major bleeding in 3 cases; access site related major complication in 1 case,AKI stage 3 in 3 cases (6.3%),minor stroke in 1 case (2.1%).Thirty-day survival rate was 89.6%.There were 5 deaths in total (10.4%):4 in TA group (20%) and 1 in TF group (3.6%).Conclusion The procedural success rate and 30-day mortality were acceptable in these high risk patients with Edwards prosthetic valves in the first 48 TAVI.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2011]版:
大类 | 4 区 医学
小类 | 4 区 医学:内科
最新[2023]版:
大类 | 3 区 医学
小类 | 3 区 医学:内科
JCR分区:
出版当年[2010]版:
Q3 MEDICINE, GENERAL & INTERNAL
最新[2023]版:
Q1 MEDICINE, GENERAL & INTERNAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2010版] 出版当年五年平均 出版前一年[2009版] 出版后一年[2011版]

第一作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院