当前位置: 首页 > 详情页

Real-Time Continuous Neuromonitoring Combines Transcranial Cerebral Doppler with Near-Infrared Spectroscopy Cerebral Oxygen Saturation During Total Aortic Arch Replacement Procedure: A Pilot Study

文献详情

资源类型:

收录情况: ◇ SCIE

机构: [1]Chinese Acad Med Sci, Dept Cardiopulm Bypass, Peking Union Med Coll, Fuwai Hosp, Beijing 100037, Peoples R China; [2]Chinese Acad Sci, Cardiovasc Inst, Peking Union Med Coll, Beijing 100037, Peoples R China; [3]Daqing Oilfield Gen Hosp, Dept Anesthesiol, Daqing City, Peoples R China; [4]Capital Med Univ, Dept Cardiopulm Bypass, Beijing Anzhen Hosp, Beijing, Peoples R China; [5]Chinese Acad Med Sci, Dept Cardiopulm Bypass, Peking Union Med Coll, Fuwai Hosp, 167 Beilishi Rd, Beijing 100037, Peoples R China
出处:
ISSN:

摘要:
The purpose of this investigation was to use combined transcranial cerebral Doppler (TCD) and near-infrared spectroscopy cerebral oxygen saturation (NIRS) during total aortic arch replacement (TAAR) to monitor middle cerebral artery blood flow velocity and regional cerebral oximetry (rSO(2)) changes to provide a clinical basis for protective measures that may decrease injury of the central nervous system. Consecutive 12 adult patients underwent deep hypothermic circulatory arrest (DHCA) and antegrade selective cerebral perfusion (ASCP) during TAAR. A TCD probe was placed at the temporal windows after induction of anesthesia and the NIRS probe placed on the forehead of patients to collect perioperative, intraoperative, and postoperative hemodynamic parameters, and cerebral blood flow (CBF) and rSO(2) during cardiopulmonary bypass (CPB). In this retrospective case series, all patients survived, and there were no postoperative neurologic complications. There was no significant correlation between the mean arterial pressure and rSO(2). The middle cerebral artery mean velocity (VmMCA) and rSO(2) were significantly correlated, and main pump flow significantly correlated with rSO(2). After ASCP, VmMCA, rSO(2), and venous oxygen saturation were significantly lower than before ASCP, but VmMCA and rSO(2) returned to pre-CPB levels postoperatively. After off pump, the flow of ASCP showed a significant positive correlation with VmMCA and rSO(2). During DHCA when ASCP flow was lower than 5 ml/kg/min, TCD could not detect the MCA blood flow signal. When the flow of ASCP was above keeping around 10 ml/kg/min, MCA CBF velocity was maintained and rSO(2) > 45%. The combination of TCD and NIRS can be effective in monitoring brain function during DHCA with ASCP and may provide a guide for decreasing brain injury during the TAAR procedure. ASAIO Journal 2012; 58:122-126.

语种:
被引次数:
WOS:
中科院(CAS)分区:
出版当年[2011]版:
大类 | 4 区 医学
小类 | 4 区 工程:生物医学 4 区 移植
最新[2023]版:
大类 | 3 区 医学
小类 | 3 区 工程:生物医学 3 区 移植
JCR分区:
出版当年[2010]版:
Q3 ENGINEERING, BIOMEDICAL Q4 TRANSPLANTATION
最新[2023]版:
Q2 ENGINEERING, BIOMEDICAL Q2 TRANSPLANTATION

影响因子: 最新[2023版] 最新五年平均 出版当年[2010版] 出版当年五年平均 出版前一年[2009版] 出版后一年[2011版]

第一作者:
第一作者机构: [2]Chinese Acad Sci, Cardiovasc Inst, Peking Union Med Coll, Beijing 100037, Peoples R China;
通讯作者:
通讯机构: [1]Chinese Acad Med Sci, Dept Cardiopulm Bypass, Peking Union Med Coll, Fuwai Hosp, Beijing 100037, Peoples R China; [5]Chinese Acad Med Sci, Dept Cardiopulm Bypass, Peking Union Med Coll, Fuwai Hosp, 167 Beilishi Rd, Beijing 100037, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16461 今日访问量:0 总访问量:871 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院