Low dose 320-row CT for left atrium and pulmonary veins imaging-the feasibility study

文献详情

资源类型:

收录情况: ◇ SCIE

机构: [1]Capital Med Univ, An Zhen Hosp, Dept Radiol, Beijing 100029, Peoples R China
出处:
ISSN:

关键词: X-ray computed Tomography Atrial fibrillation Radiation dose

摘要:
Objective: To evaluate the feasibility of low dose target-CTA volume scan for left atrium and pulmonary veins imaging using 320-row CT. Methods: Forty-two patients (females 12, males 30; mean age 55.2 years; mean body mass index (BMI) 25.7 kg/m(2)) with persistent or intermittent atrial fibrillation before catheter ablation were enrolled in this study. Scan protocol was target-CTA volume scan under prospective ECG-gating. The target of the exposure was only set at 40% of the R-R interval (which was at the left atrium maximal volume). The exposure time was minimal setting (350 ms). Tube voltage 100 kV (BMI <= 25 kg/m(2)) or 120 kV (BMI > 25 kg/m(2)), tube current 350-420 mA, and field of view of 180 mm x 180 mm-200 mm x 200 mm were used. The scanning range was from the level of the tracheal bifurcation to the diaphragm, and enabled to cover the left atrium and central pulmonary veins (120-140 mm). All of patients were divided into two groups according kV setting (100 kV and 120 kV). The image quality (good, moderate and poor) was evaluated by two reviewers. The CT-attenuation, image noise and contrast to noise ratio (CNR) of left atrium and every pulmonary vein branch were evaluated, respectively. The effective dose (ED) was calculated using a conversion coefficient for the chest 0.017. Results: Of 42 patients, the image quality was good in 26 cases (62%) and moderate in 16 cases (38%). There was no statistical difference in the CT-attenuation and CNR of left atrium and central pulmonary veins between the two groups (P > 0.05). The mean ED was 1.90 +/- 0.19 mSv (range 1.57-2.25 mSv) in 100 kV group, and 3.83 +/- 0.31 mSv (range 3.39-4.54 mSv) in 120 kV group. Conclusions: The low dose target-CTA volume scan is feasible in pulmonary veins and left atrium imaging using 320-row CT. Slim patients can be scanned at 100 kV setting without loss of image quality. (C) 2011 Elsevier Ireland Ltd. All rights reserved.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2011]版:
大类 | 3 区 医学
小类 | 3 区 核医学
最新[2023]版:
大类 | 3 区 医学
小类 | 3 区 核医学
JCR分区:
出版当年[2010]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2010版] 出版当年五年平均 出版前一年[2009版] 出版后一年[2011版]

第一作者:
第一作者机构: [1]Capital Med Univ, An Zhen Hosp, Dept Radiol, Beijing 100029, Peoples R China
通讯作者:
通讯机构: [1]Capital Med Univ, An Zhen Hosp, Dept Radiol, Beijing 100029, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16461 今日访问量:0 总访问量:871 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院