当前位置: 首页 > 详情页

Prospective ECG-gated 320-row CT angiography of the whole aorta and coronary arteries

文献详情

资源类型:

收录情况: ◇ SCIE

机构: [1]Capital Med Univ, Dept Radiol, Beijing An Zhen Hosp, Beijing 100029, Peoples R China; [2]Capital Med Univ, Key Lab Remodeling Related Cardiovasc Dis, Beijing An Zhen Hosp, Minist Educ, Beijing 100029, Peoples R China
出处:
ISSN:

关键词: 320 row-detector Volume computed tomography CT angiography (CTA) Prospective ECG gating Radiation dose

摘要:
To investigate the feasibility of using a prospective ECG-gated wide-volume protocol in CT angiography (CTA) of the whole aorta and coronary arteries (CA). A total of 61 consecutive patients with suspected acute aortic diseases underwent CTA of the whole aorta using a prospective ECG-gated wide-volume CT protocol without heart rate (HR) control. The exposure window was set at 40-50 % of R-R interval (HR a parts per thousand yen70 bpm) or 70-80 % of R-R interval (HR < 70 bpm) in a single heartbeat. The image quality of the ascending aorta, aortic valve and CA was evaluated for motion artefacts. The mean attenuation was measured at different levels of the aorta. The radiation dose and contrast medium volume were recorded. All of the examinations were performed successfully. The image quality was acceptable in the ascending aorta, aortic valve (100 %) and CA (94.4 %). The mean radiation dose was 18.42 +/- 5.02 mSv. Of 61 patients, 14 were diagnosed with aortic aneurysm and 35 were diagnosed with aortic dissection or intramural haematoma. Coronary artery stenosis was detected in 12 patients. For patients with aortic diseases, CTA of the whole aorta using a prospective ECG-gated wide-volume protocol has the potential to provide additional information about the CA and aortic valve with lower radiation exposure. aEuro cent Computed tomography is increasingly used to assess the coronary arteries and the aorta. aEuro cent This novel study investigates prospective ECG-gated wide-volume 320-row CT angiography. aEuro cent Heart rate variation did not influence the image quality of coronary arteries. aEuro cent Abnormalities in the coronary arteries and aorta can be simultaneously assessed noninvasively.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2011]版:
大类 | 2 区 医学
小类 | 2 区 核医学
最新[2023]版:
大类 | 2 区 医学
小类 | 2 区 核医学
JCR分区:
出版当年[2010]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2010版] 出版当年五年平均 出版前一年[2009版] 出版后一年[2011版]

第一作者:
第一作者机构: [1]Capital Med Univ, Dept Radiol, Beijing An Zhen Hosp, Beijing 100029, Peoples R China; [2]Capital Med Univ, Key Lab Remodeling Related Cardiovasc Dis, Beijing An Zhen Hosp, Minist Educ, Beijing 100029, Peoples R China
通讯作者:
通讯机构: [1]Capital Med Univ, Dept Radiol, Beijing An Zhen Hosp, Beijing 100029, Peoples R China; [2]Capital Med Univ, Key Lab Remodeling Related Cardiovasc Dis, Beijing An Zhen Hosp, Minist Educ, Beijing 100029, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16461 今日访问量:0 总访问量:871 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院