To evaluate the accuracy and feasibility of right ventricular function parameters measurement using 320-slice volume cardiac CT. Retrospective analysis of 50 consecutive patients (23 men, 27 women) with suspected pulmonary diseases was performed in electrocardiogram (ECG)-gated cardiac CT and cardiac magnetic resonance (CMR). Parameters including right ventricular end- diastolic volume (RVEDV), right ventricular end- systolic volume (RVESV), right ventricular stroke volume (RVSV), right ventricular cardiac output (RVCO), and right ventricular ejection fraction (RVEF) were semi-automatically and separately calculated from both CT and CMR data. Significant difference between measurements was measured by paired t test and two-variable linear regression analysis with Pearson's correlation coefficient. Bland-Altman analysis was performed in each pair of parameters. There was little variability between the measurements by the two observers (kappa = 0.895-0.980, P < 0.05). There was good correlation between all parameters obtained by CT and CMR (P < 0.001): RVEDV (108.5 +/- 21.9 ml, 113.5 +/- 24.8 ml, r = 0.944), RVESV (69.8 +/- 33.4 ml, 73.2 +/- 35.4 ml, r = 0.972), RVSV (39.0 +/- 13.2 ml, 40.2 +/- 13.3 ml, r = 0.977), RVCO (2.6 +/- 0.7 l, 2.6 +/- 0.7 l. r = 0.958), RVEF (38.8 +/- 19.1 %, 39.1 +/- 19.3 %, r = 0.990), and there was no significant difference between CT and CMR measurements in RVEF (n = 50, t = -0.677, P > 0.05). 320-slice volume cardiac CT is an accurate non-invasive technique to evaluate RV function.
语种:
外文
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2011]版:
大类|4 区医学
小类|3 区核医学4 区心脏和心血管系统
最新[2023]版:
大类|4 区医学
小类|4 区心脏和心血管系统4 区核医学
JCR分区:
出版当年[2010]版:
Q2RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGINGQ2CARDIAC & CARDIOVASCULAR SYSTEMS
最新[2023]版:
Q3CARDIAC & CARDIOVASCULAR SYSTEMSQ3RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
第一作者机构:[1]Capital Med Univ, Dept Radiol, Anzhen Hosp, Beijing 100029, Peoples R China;
通讯作者:
通讯机构:[1]Capital Med Univ, Dept Radiol, Anzhen Hosp, Beijing 100029, Peoples R China;[2]Capital Med Univ, Dept Radiol, Anzhen Hosp, Anzhen Rd 2, Beijing 100029, Peoples R China
推荐引用方式(GB/T 7714):
Huang Xiaoyong,Pu Xin,Dou Ruiyu,et al.Assessment of right ventricular function with 320-slice volume cardiac CT: comparison with cardiac magnetic resonance imaging[J].INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING.2012,28(2 SUPPL.):87-92.doi:10.1007/s10554-012-0156-8.
APA:
Huang, Xiaoyong,Pu, Xin,Dou, Ruiyu,Guo, Xi,Yan, Zixu...&Lu, Biao.(2012).Assessment of right ventricular function with 320-slice volume cardiac CT: comparison with cardiac magnetic resonance imaging.INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING,28,(2 SUPPL.)
MLA:
Huang, Xiaoyong,et al."Assessment of right ventricular function with 320-slice volume cardiac CT: comparison with cardiac magnetic resonance imaging".INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING 28..2 SUPPL.(2012):87-92